Document
www.DataSheet4U.com
RoHS Compliant
Broadband CATV, 10dB Coupler 5-1000 MHz
Features
• • • • • • Surface mount Typical coupling +10dB 260°C reflow compatible RoHS* compliant RoHS version of MACPES0034. Available on tape and reel, reel quantity 2000
MACPCT0039 V1P
Schematic
Description
M/A-COM’s MACPCT0039 is a 10dB broadband Coupler in a low cost, surface mount package. It offers low loss, good isolation, good input/output matching and exceptional coupling repeatability. Ideally suited for high volume CATV/Broadband applications.
Pin Configuration
Pin No.
1 2 3 4 5
Case Style: SM-138
Function
Input Ground Coupled
Isolated (external 75 Ohms termination) Output
Ordering Information
Part Number
MACPCT0039TR MACP-007982-CT39TB
Package
2000 piece reel Customer Test Board Dimensions in inches [mm] Tolerance: .xx ± .02, .xxx ± .010
Note: Reference Application Note M513 for reel size information. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
RoHS Compliant
Broadband CATV, 10dB Coupler 5-1000 MHz MACPCT0039 V1P
Electrical Specifications: TA = 25°C, Z0 = 75Ω 1
Parameter
Coupling Coupling Flatness Main Line Loss
Test Conditions
5 - 870 MHz 870 - 1000 MHz 5 - 1000 MHz 5—500 MHz 500 - 870 MHz 870 - 1000 MHz 5 - 1000 MHz 5 - 1000 MHz 5 - 1000MHz 5 - 500 MHz 500 - 1000 MHz
Units
dB dB dB dB dB dB dB dB dB dB dB
Min
18 18 18 25 20
Typ
10 10 0.9 1.2 1.6 20 20 20 30 23
Max
± 0.5 ±0.9 1.0 1.3 1.5 1.8 -
Input Return Loss Output Return Loss Coupling Return Loss Isolation
Absolute Maximum Ratings 1,2
Parameter
Max Input Power DC current Operating Temperature Storage Temperature
Recommended PCB Configuration
Absolute Maximum
250mW 30mA -40°C to +85°C -55°C to +100°C
1. Exceeding any one or combination of these limits may cause permanent damage to this device. 2. M/A-COM does not recommend sustained operation near these survivability limits. 2
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.57.