Power Switch. MASW-008566 Datasheet

MASW-008566 Switch. Datasheet pdf. Equivalent

Part MASW-008566
Description GaAs SP4T 2.5 V High Power Switch
Feature www.DataSheet4U.com RoHS Compliant MASW-008566 V1 Functional Schematic GaAs SP4T 2.5 V High Power .
Manufacture Tyco Electronics
Datasheet
Download MASW-008566 Datasheet



MASW-008566
www.DataSheet4U.com
GaAs SP4T 2.5 V High Power Switch
DC - 3.0 GHz
RoHS
Compliant
MASW-008566
V1
Features
Low Voltage Operation: 2.5 V
Low Harmonics: < -65 dBc at +34 dBm & 1 GHz
Low Insertion Loss: 0.65 dB at 1 GHz
High Isolation: 23 dB at 2 GHz
0.5 micron GaAs PHEMT Process
Lead-Free 4x4 mm PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of MASWSS0118
Description
M/A-COM’s MASW-008566 is a GaAs PHEMT
MMIC single pole four throw (SP4T) high power
switch in a low cost 4 mm 16-lead PQFN package.
The MASW-008566 is ideally suited for applications
where high power, low control voltage, low insertion
loss, high isolation, small size, and low cost are
required.
Typical applications are for GSM and DCS handset
systems that connect separate transmit and receive
functions to a common antenna, as well as other
handset and related applications. This part can be
used in all systems operating up to 3.0 GHz
requiring high power at low control voltage.
The MASW-008566 is fabricated using a 0.5 micron
gate length GaAs PHEMT process. The process
features full passivation for performance and
reliability.
Ordering Information
Part Number
MASW-008566-TR3000
Package
3000 piece reel
1. Reference Application Note M513 for reel size information
Functional Schematic
Pin Configuration
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Pin Name
V1
RF1
GND
RF2
GND
V2
V3
GND
RF3
GND
GND
RF4
GND
V4
GND
ANT
Paddle 2
Description
Control 1
RF Port 1
RF Ground
RF Port 2
RF Ground
Control 2
Control 3
RF Ground
RF Port 3
RF Ground
RF Ground
RF Port 4
RF Ground
Control 4
RF Ground
Antenna Port
RF Ground
2. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MASW-008566
GaAs SP4T 2.5 V High Power Switch
DC - 3.0 GHz
RoHS
Compliant
MASW-008566
V1
Electrical Specifications: TA = 25°C, Z0 = 50 Ω 3
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss 4
Isolation
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
DC – 1 GHz
1 – 2 GHz
2 - 3 GHz
dB — 0.65 0.85
dB — 0.80 1.00
dB — 1.00 —
dB 27 29.0
dB 21 23.0
dB — 18.5
Return Loss
DC – 3 GHz
dB — 20 —
IP3
IP2
P.1dB
2nd Harmonic
3rd Harmonic
Trise, Tfall
Ton, Toff
Transients
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
57
Two Tone +26 dBm, 5 MHz Spacing, > 50 MHz
VC = 0 V / 2.5 V
dBm
81
VC = 0 V / 2.5 V
dBm
38
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
dBc — -80 -71
1 GHz, PIN = +34 dBm, VC = 0 V / 2.5 V
dBc — -68 -65
10% RF to 90% RF, 90% to 10% RF, VC = 0 V / 2.5 V
µS — 0.2 —
50% control to 90% RF, 50% control to 10% RF, VC = 0 V / 2.5 V µS
0.2
mV — 35 —
Control Current
VC = 0 V / 2.5 V, 34 dBm
µA — 10 50
3. External DC blocking capacitors are required on all RF ports.
4. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 - 500 MHz, 39 pF for 0.5 - 3 GHz.
Absolute Maximum Ratings 5,6
Parameter
Absolute Maximum
Input Power
(0.5 - 3.0 GHz, 2.5 V Control)
+38 dBm
Voltage
± 8.5 volts
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged by
static electricity. Proper ESD control techniques should
be used when handling these devices.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
Truth Table 7,8
V1 V2 V3 V4
ANT- ANT- ANT- ANT-
RF1 RF2 RF3 RF4
1 000
On Off Off Off
0 100
Off On Off Off
0 010
Off Off On Off
0 001
Off Off Off On
7. Differential voltage, V (state 1) -V (state 2), must be 2.5 V
minimum.
8. 0 = -5 V to +2.5 V, 1 = -2.5 V to +5 V
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)