Power Switch. MASWSS0091 Datasheet

MASWSS0091 Switch. Datasheet pdf. Equivalent

Part MASWSS0091
Description GaAs SP6T 2.5 V High Power Switch
Feature www.DataSheet4U.com GaAs SP6T 2.5 V High Power Switch Dual / Tri / Quad-Band GSM Applications Featu.
Manufacture Tyco Electronics
Datasheet
Download MASWSS0091 Datasheet



MASWSS0091
www.DataSheet4U.com
GaAs SP6T 2.5 V High Power Switch
Dual / Tri / Quad-Band GSM Applications
Features
Supplied as Known Good Die
Dual/tri/quad-band GSM/GPRS/EDGE
Low Voltage: 2.5V Operation
Low Harmonics: -72 dBc at +35 dBm & 1 GHz
Low Insertion Loss: 0.5 dB at 1 GHz
High Tx-Rx Isolation: 38 dB at 2 GHz
Description
M/A-COM’s MASWSS0091 is a GaAs PHEMT
MMIC single pole six throw (SP6T) high power
switch die. The MASWSS0091 is ideally suited for
applications where high power, low control voltage,
low insertion loss, high isolation, small size and low
cost are required. The MASWSS0091 is designed
for dual-, tri-, and quad-band GSM and DCS/PCS
handset systems that connect separate transmit and
receive functions to a common antenna, and can be
used in all systems operating up to 2.5 GHz
requiring high power at low control voltage.
The MASWSS0091 is fabricated using a 0.5 micron
gate length GaAs PHEMT process. The process
features full passivation for performance and
reliability.
Ordering Information
Part Number
MASWSS0091SMB
MASWSS0091-DIE
Package
Sample Test Board
Separated die on Grip Ring
Note: Die quantity varies.
Absolute Maximum Ratings 1
Parameter
Input Power
(0.5 - 2.5 GHz, 2.5V Control)
Voltage
Operating Temperature
Storage Temperature
Absolute Maximum
+38 dBm
±8.5 volts
-40°C to +85°C
-65°C to +150°C
1. Exceeding any one or combination of these limits may
cause permanent damage to the device.
Die Layout
Tx1 VTx1
MASWSS0091
V6
ANT
VTx2
Tx2
ANT
VRx1 Rx1 GND Rx2 VRx2 VRxC VRx3 Rx3 GND Rx4 VRx4
Pad Layout
PAD Name
Tx1
VTx1
ANT
VTx2
Tx2
VRx4
Rx4
GND
Rx3
VRx3
VRxC
VRx2
Rx2
GND
Rx1
VRx1
ANT
Description
Tx1 Port
Tx1 Control
Antenna Port
Tx2 Control
Tx2 Port
Rx4 Control
Rx4 Port
Ground
Rx3 Port
Rx3 Control
Rx Common Control
Rx2 Control
Rx2 Port
Ground
Rx1 Port
Rx1 Control
Redundant ANT Pad
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MASWSS0091
GaAs SP6T 2.5 V High Power Switch
Dual / Tri / Quad-Band GSM Applications
MASWSS0091
V6
Electrical Specifications: TA = 25°C, Vc = 0V/2.5V, Z0 = 50 Ohms 2
Parameter
Tx Insertion Loss3
Rx Insertion Loss3
Tx to Rx Isolation
Tx to Tx Isolation
Return Loss
Tx P0.1dB
Rx P1dB
2nd Harmonic
3rd Harmonic
Trise, Tfall
Ton, Toff
Transients
Control Current
Test Conditions
0.5 - 1 GHz
1 - 2 GHz
0.5 - 1 GHz
1 - 2 GHz
0.5 - 1 GHz
1 - 2 GHz
0.5 - 1 GHz
1 - 2 GHz
0.5 - 2.5 GHz
1 GHz
1 GHz
1 GHz, PIN = +35 dBm, 100% Duty Cycle
1 GHz, PIN = +35 dBm, 100% Duty Cycle
10% to 90% RF, 90% to 10% RF
50% control to 90% RF,
and 50% control to 10% RF
In Band
Units
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBc
dBc
µS
µS
mV
µA
Min.
40
22
2. External DC blocking capacitors are required on all RF ports.
3. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 100 pF for 0.5 GHz - 2.0 GHz.
Typ.
0.5
0.65
1.0
1.3
45
38
26
17
20
41
25
-78
-72
0.2
0.2
70
20
Max.
0.7
0.9
1.2
1.6
-67
-67
80
Functional Schematic
100pF
Tx1 VTx1
100pF
100pF
ANT
VTx2
Tx2
Qualification
Qualified to M/A-COM specification REL-201,
Process Flow –2.
Handling Procedures
Please observe the following precautions to avoid
damage:
VRx1
VRxC
VRx2
VRx3
VRx4
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Rx1 GND Rx2
Rx3 GND Rx4
100pF
100pF
100pF
100pF
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)