Terminated Switch. MASWSS0201 Datasheet

MASWSS0201 Switch. Datasheet pdf. Equivalent

Part MASWSS0201
Description SPDT Terminated Switch
Feature www.DataSheet4U.com RoHS Compliant MASWSS0201 V1 GaAs Broadband 75 Ohm Default-On, SPDT Terminated.
Manufacture Tyco Electronics
Datasheet
Download MASWSS0201 Datasheet



MASWSS0201
www.DataSheet4U.com
RoHS
Compliant
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
MASWSS0201
V1
Features
Ideal for CATV, DTV, DVR, STB Applications
Default-On in Unpowered State (RFC-RF1 Path)
Broadband Performance: DC-2.5 GHz
Low Insertion Loss: 1.1 dB at 1 GHz
High Isolation: > 60dB @ 100MHz
Single Control Operation
Power Handling: > 20 dBm P1dB
Lead-Free 3 mm 12-lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Configurable for Non-terminated Operation
Description
M/A-COM’s MASWSS0201 is a broadband GaAs
PHEMT MMIC SPDT terminated switch in a low
cost, lead-free 3 mm 12-lead PQFN package. The
MASWSS0201 is ideally suited for applications
where an unpowered on state is critical in a single
control line SPDT terminated switch. The
unpowered condition is the same as the VC = 0
condition. This part can also be configured as a
reflective switch with minimal impact to the RF
performance.
The MASWSS0201 delivers high isolation, low
insertion loss and high linearity up to 2.5 GHz.
The MASWSS0201 is fabricated using a 0.5 micron
gate length GaAs E/D PHEMT process. The
process features full passivation for performance
and reliability.
Ordering Information 1
Part Number
Package
MASWSS0201TR-3000
3000 piece reel
MASWSS0201SMB
Sample Test Board
(Includes 5 Samples)
1. Reference Application Note M513 for reel size information.
Functional Schematic
Pin Configuration 2
Pin No.
Pin Name
Description
1 N/C No Connection
2 RF1
RF Port 1
3
Term 1 GND3
Termination 1 Ground
4 GND
Ground
5 N/C No Connection
6 GND
Ground
7
Term 2 GND3
Termination 2 Ground
8 RF2
RF Port 2
9 VC
Control
10 GND
Ground
11 RFC
RF Input
12 GND
Ground
13
Paddle 4
RF and DC Ground
2. M/A-COM recommends that all unused (N/C) pins be
connected to ground. All data on this datasheet was taken
with N/C pins connected to ground.
3. Terminated grounds require DC blocking capacitors; see
application schematic.
4. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MASWSS0201
RoHS
Compliant
GaAs Broadband 75 Ohm Default-On, SPDT Terminated Switch
DC - 2.5 GHz
MASWSS0201
V1
Electrical Specifications: TA = 25°C, Z0 = 75 Ω, VC = 0 V/3 V, PIN = 0 dBm 5
Parameter
Test Conditions
Units Min.
Typ.
Insertion Loss RFC to RF1
(VC = 0V)
100 MHz
1.0 GHz
2.0 GHz
dB —
dB —
dB —
0.9
1.0
1.3
Insertion Loss RFC to RF2
(VC = 3V)
100 MHz
1.0 GHz
2.0 GHz
dB —
dB —
dB —
1.0
1.2
1.5
Isolation
100 MHz
1.0 GHz
2.0 GHz (RFC - RF1)
2.0 GHz (RFC - RF2)
dB 60
dB 40
dB —
dB —
65
45
38
43
Return Loss
DC - 2.0 GHz
dB —
25
IIP2
(VC = 0V / 3V / 5V)
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
dBm
dBm
— 54 / 51 / 53
— 72 / 70 / 70
IIP3
(VC = 0V / 3V / 5V)
Two Tone, +5 dBm/Tone, 10 MHz Spacing
100 MHz
1.0 GHz
dBm
dBm
— 38 / 38 / 39
— 41 / 44 / 44
Input P1dB
(VC = 0V / 3V / 5V)
T-rise
T-fall
100 MHz
1.0 GHz
10% to 90% RF
90% to 10% RF
dBm
dBm
µS
nS
— 21 / 21 / 22
— 29 / 28 / 29
— 1.4
— 12
Ton
50% control to 90% RF
µS —
1.6
Toff
50% control to 10% RF
nS —
12
Transients
mV —
550
Control Current
VC = 3V
µA —
250
5. Electrical specifications apply to terminated configuration only.
Max.
1.75
1.85
1.65
1.85
500
Absolute Maximum Ratings 6,7
Parameter
Absolute Maximum
Input Power @ 100 MHz
+22 dBm
Input Power @ 1 GHz
+29 dBm
Operating Voltage
Operating Temperature
Storage Temperature
+8.5 volts
-40°C to +85°C
-65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
7. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table 8,9,10
Control
VC
0
1
RFC-RF1
On
Off
RFC-RF2
Off
On
8. External DC blocking capacitors are required on all RF ports.
9. 0 = 0 ± 0.1 V, 1 = +2.9 V to +5 V.
10. The unpowered on state is the same as VC=0.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)