Synthesizer. MASYVS0006-1950 Datasheet

MASYVS0006-1950 Synthesizer. Datasheet pdf. Equivalent

Part MASYVS0006-1950
Description Synthesizer
Feature www.DataSheet4U.com Synthesizer , SMT 1920 — 2000 MHz, 100 & 200 kHz Features ♦ Fully Integrated VC.
Manufacture Tyco Electronics
Total Page 3 Pages
Datasheet
Download MASYVS0006-1950 Datasheet



MASYVS0006-1950
www.DataSheet4U.com
Synthesizer , SMT
1920 — 2000 MHz, 100 & 200 kHz
Features
Fully Integrated VCO, PLL, Loop Filter
High Performance, Low Cost
Miniature SMT Package (LSM6)
Description
This synthesizer design integrates a high performance VCO, PLL,
IC and discrete loop filter in a surface mount package. This SMT
package provides electrical shielding, easy PCB assembly and re-
peatable performance. The synthesizer is designed for use in wire-
less base stations.
M/A-COM synthesizers are manufactured in an ISO9001 certified
facility, incorporating surface mount assembly and automated elec-
trical testing. This ensures consistent electrical performance and
quality over volume production quantities.
MASYVS0006-1950
Rev: F
Electrical Specifications1:
TA = +25°C, Z0 = 50 Ohms, Vcc1 = 5V, Vcc2 = 3.3V.
Parameter
Test Conditions
Frequency Range
RF Output Power
Over Top 2
Over Top 2
Phase Noise
SSB at 100 Hz offset from carrier
SSB at 1 kHz offset from carrier
SSB at 10 kHz offset from carrier
SSB at 100 kHz offset from carrier
SSB at 1.0 MHz offset from carrier
Integrated Phase Noise
100 Hz to 1 MHz bandwidth
Harmonic Suppression
Spurious Suppression
(Non-Harmonic)
Phase comparison frequency
( ± 100 kHz or ± 200 kHz)
Reference breakthrough ( ± 10 MHz)
Frequency Lock Time
VCO Supply Current (ICC1)
Over Fout , Measured to within ± 50 Hz
Recommended operating condition
PLL Supply Current (ICC2)
VCO Power Supply (VCC1)
PLL Power Supply (VCC2)
Recommended operating condition
Recommended operating condition
Recommended operating condition
Units
MHz
dBm
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Degree
dBc
dBc
dBc
ms
mA
mA
V
V
1. All specification limits are indicated values @ +25 ºC and apply over Fout unless otherwise stated.
2. Top = -40ºC to +85ºC operating temperature.
Min
1920
-3.0
+4.75
+2.85
Typ
1.2
25
6
+5.00
+3.30
Max
2000
+3.0
-65
-65
-90
-118
-138
-15
-65
-90
50
30
10
+5.25
+3.45
1
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without noti ce. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MASYVS0006-1950
Synthesizer , SMT
1920 — 2000 MHz, 100 & 200 kHz
Electrical Specifications1: (cont’d)
MASYVS0006-1950
Parameter
Step Size (F)
Reference Frequency (FR)
PLL Programming
PLL Lock Monitor Output
Test Conditions
Units
Min
Typ
Recommended operating limit
kHz
100/200
1.0 V pp ± 0.2V square wave with input filter
MHz
5
3-wire serial CMOS IAW LMX2326, Charge Pump 1 mA
Logic high = VCC2 x 0.8 Min and Logic low = V CC2 x 0.2 Max
Locked = VCC2 - 0.4 Min , Unlocked = 0.4V Max
Max
40
Pin Configuration
Pin No.
1
2
3
4
5
6
7
Function
V CC2
GND
REF I/P
GND
V CC1
GND
RF O/P
Pin No.
8
9
10
11
12
13
14
Function
GND
Lock Detect
Clock
Data
Load Enable
GND
GND
Functional Block Diagram
Absolute Maximum Ratings
TA = +25°C
Parameter
Absolute Maximum
VCO Supply Voltage (VCC1)
PLL Supply Voltage (VCC2)
Reference Frequency Level
Data, Clock, Strobe
Voltages
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to V cc + 0.3 V
Operating Temperature
Storage Temperature
Solder Assembly
Temperature
-40°C to +85°C
-45°C to +120°C
See App Note M2032
1. Operation of this device above any one of these parameters
may cause permanent damage.
2. Static sensitive, observe appropriate handling precautions.
Environmental Specifications
Devices are designed to function after exposure to the
shock, vibration, thermal shock and moisture conditions
typically encountered in base station and other infra-
structure environments.
1. The diagram above shows a typical application.
2. The Reference input and RF output are internally AC cou-
pled.
3. The diagram applies when digital lock detect is selected. For
analog open-drain mode, a filter is required. See AN3003 for
design information.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without noti ce. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
Ordering Information
Part Number
MASYVS0006-1950 B
MASYVS0006-1950 T
MASYVS0006-1950 R
Package
Bulk Packaging
Tape and Reel (300/Reel) 1
Reverse Tape and Reel
(300/Reel) 1
1. See application note M513.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)