Insensitive Mixer. MD-169 Datasheet

MD-169 Mixer. Datasheet pdf. Equivalent

Part MD-169
Description Termination Insensitive Mixer
Feature www.DataSheet4U.com Termination Insensitive Mixer, 1 MHz - 3.5 GHz Features • Intermodulation Ratio.
Manufacture Tyco
Datasheet
Download MD-169 Datasheet



MD-169
www.DataSheet4U.com
Termination Insensitive Mixer,
1 MHz - 3.5 GHz
Features
Intermodulation Ratio is Insensitive to Port
Mismatches
VSWR: <2.0:1 Typical Midband
Isolation: 35 dB Typical Midband
Impedance: 50 Ohms Nominal
Maximum Input Power: 350 mW Max @ 25°C,
Derated to 85°C @ 3.2 mW/°C
LO Power: +24 dBm Max.
MIL-STD-883 Screening Available
Description
The unique design of the termination insensitive
mixer (TIM) enables it to apply high reverse voltage
to diodes during their “off” phase, in the LO cycle.
This allows for higher power level performance with
minimum distortion. In addition the TIM has internal
loads that provide a good match and also absorb
mixer generated LO frequency terms. Combined,
these features give the mixer its
insensitivity to external mismatches, plus superior
VSWR.
C-7 (MDC-169)
FP-2 (MD-169)
SF-1 (MDS-169)
MD-/MDC-/MDS-169
V5
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MD-169
Termination Insensitive Mixer,
1 MHz - 3.5 GHz
MD-/MDC-/MDS-169
V5
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Frequency Range
Conversion Loss
RF, LO Ports
IF Port
0.001 - 3.5
5 - 1500
5 - 1000 MHz2
5 - 3000 MHz3
1 - 3500 MHz
Units
GHz
MHz
dB
dB
dB
Min
Typ
Isolation
LO to RF
LO to IF
RF to IF
RF Input
SSB Noise Figure
Typical Two-Tone IM
Ratio
1 dB Compression
1 dB Desensitization
Within 1 dB of Conversion Loss
Max
with a –10 dBm input, each tone
625 MHz and 35 MHz IF
3rd Order
Intermodulation Ratio
Degradation
@ IF VSWR 3:1
5 - 1000 MHz
1 - 3500 MHz
5 - 1000 MHz
1 - 3500 MHz
10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
10 MHz
500 MHz
3000 MHz
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dB
dB
dB
dB
30
20
30
20
30
20
18
+7
+5
55
58
56
3
1. All specifications apply when operated at +10 dBm available LO power with 50 Ohm source and load impedance.
2. For IF Frequencies of 5 - 300 MHz and RF of –10 dBm or less.
3. For MDC-169, add 1.0 dB to conversion loss.
Max
7
8
10
Electrical Specifications (MDS-169): TA = -55°C to +85°C
Frequency: RF, LO Ports = 1 - 3500 MHz, IF Port = 5-1500 MHz
Parameter
Conversion Loss
Isolation
Test Conditions
LO @ +10 dBm
IF @ 60 MHz
LO to RF
LO to IF
RF to IF
Frequency
Units
Min
Typ
Max
5 - 1000 MHz
1000 - 3000 MHz
1 - 3500 MHz
dB
dB
dB
— 6.5 7.0
— 7.5 9.0
— 8.0 10.0
5 - 1000 MHz
1 - 3500 MHz
5 - 1000 MHz
1 - 3500 MHz
10 - 500 MHz
1 - 3000 MHz
1 - 3500 MHz
dB 30 35 —
dB 20 25 —
dB 30 35 —
dB 20 25 —
dB 30 35 —
dB 20 25 —
dB 18 23 —
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)