Termination-Insensitive Mixer. MDC-164 Datasheet

MDC-164 Mixer. Datasheet pdf. Equivalent

Part MDC-164
Description Termination-Insensitive Mixer
Feature www.DataSheet4U.com Termination-Insensitive Mixer, 0.5 - 9 GHz Features • Intermodulation Ratio Ins.
Manufacture Tyco Electronics
Datasheet
Download MDC-164 Datasheet



MDC-164
www.DataSheet4U.com
Termination-Insensitive Mixer,
0.5 - 9 GHz
Features
Intermodulation Ratio Insensitive to
IF Ports Mismatches
Conversion Loss: 6.5 dB Typical Midband
Maximum Input Power: 350 mW max. @ 25°C,
Derated 3.5 mW/°C
Low Power: +24 dBm Max.
MIL-STD-883 Screening Available
Description
The unique design of the termination insensitive
mixer (TIM) enables it to apply high reverse voltage
to diodes during their “off” phase, in the LO cycle.
This allows for higher power level performance with
minimum distortion. In addition the TIM has internal
loads that provide a good match and also absorb
mixer generated LO frequency terms. Combined,
these features give the mixer its insensitivity to
external mismatches, plus superior VSWR.
C-3
MDC-164
V3
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MDC-164
Termination-Insensitive Mixer,
0.5 - 9 GHz
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss2
Test Conditions
RF, LO Ports
IF Port
Frequency
0.5 - 9
10 - 2000
1 - 7 GHz
0.5 - 1 GHz
7 - 9 GHz
Isolation
LO to RF
1.5 - 7 GHz
0.5 - 9 GHz
LO to IF
1.5 - 7 GHz
0.5 - 9 GHz
RF to IF
0.5 - 9 GHz
RF Input
SSB Noise Figure
3rd Order Input
Intercept
1 dB Compression
1 dB Desensitization
Within 1 dB of Conversion Loss
Max.
2.0 GHz
8.0 GHz
MDC-164
V3
Units
Min
Typ
Max
GHz
MHz
dB
dB
dB
——
——
— 8.5
— 10.0
— 11.0
dB 17 — —
dB 13 — —
dB 20 — —
dB 17 — —
dB 17 — —
dBm
+8
dBm
+6
— ———
dBm — +15 —
dBm — +17 —
3rd Order Intercept
@ IF Termination VSWR 3:1
dB — 1.5
Degration
1. All specifications apply when operated at +13 dBm available LO power with 50 ohm source and load impedance.
2. For IF frequencies of 10 - 500 MHz and an RF of –10 dBm or lower.
3. Independent of sum frequency match.
This product contains elements protected by United States Patent Number 4,224,572
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)