Changing the Shape of Power
www.DataSheet4U.com
BLP40 AC-DC Series Data Sheet 40 Watts
Features • RoHS lead-free solder and lead-solder-exempted p...
Description
www.DataSheet4U.com
BLP40 AC-DC Series Data Sheet 40 Watts
Features RoHS lead-free solder and lead-solder-exempted products are available Industry-standard 3” x 5” footprint Main output remote sense CE marked to Low Voltage Directive (Pending) Compliance to EN61000-4-2/-3/-4/-5/-6/-8
Description The BLP40 Series’ economical and compact construction provides single or three-output ac-dc power conversion to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. The BLP40 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection
MODEL NOMINAL OUTPUT VOLTAGE (VDC) MIN-MAXIMUM OUTPUT CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 TOTAL REGULATION % 3 RIPPLE & NOISE %p-p 4
BLP40-1005 BLP40-1012 BLP40-1024
5V 12V 24V
0 to 5A 0 to 2.1A 0 to 1.1A
0 to 8A 0 to 3.3A 0 to 1.8A
9A 3.7A 1.9A
±2 ±2 ±2
1 1 1
Triple Output Model Selection
MODEL NOMINAL OUTPUT VOLTAGE (VDC) MIN-MAXIMUM OUTPUT CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 TOTAL REGULATION % 3 RIPPLE & NOISE %p-p 4
BLP40-3000
BLP40-3003*
+5V +12V -12V +5V +15V -15V
0.3 to 3A 0.1 to 1.5A 0.0 to 0.5A 0.3 to 3A 0.1 to 1.5A 0.0 to 0.5A
0.3 to 4A 0.1 to 2A 0.0 to 0.7A 0.3 to 4A 0.1 to 2A 0.0 to 0.7A
5A 3A 1 5A 2.5A 1A
±2 ±5 ±5...