Circuit Protector Elements
Circuit Protector Elements
UNH0108 (UN11008)
Circuit Protector Elements
Unit: mm
For overcurrent protection
(0.4)
(1.5...
Description
Circuit Protector Elements
UNH0108 (UN11008)
Circuit Protector Elements
Unit: mm
For overcurrent protection
(0.4)
(1.5)
6.9±0.1 (1.5)
2.5±0.1 (1.0)
3.5±0.1
0.5 max.
■ Absolute Maximum Ratings Ta = 25°C
www.DataSheet4U.com Parameter Operating ambient temperature Storage temperature Symbol Topr Tstg Rating −55 to +125 −55 to +125 Unit °C °C
1
1.0±0.1
(0.85)
2.4±0.2
0.45±0.05
2 (5.0)
3
1.25±0.05
0.55±0.1
1: For use 2: N.C. 3: For use M-B1 Package
■ Electrical Characteristics Ta = 25°C ± 3°C
Parameter Rated voltage Rated current Internal resistance Cutoff current Standard temperature rise 55 Min Typ 50 0.8 73 91 Max Unit V A mΩ °C
Cutoff time (s)
100
10
Refer to the diagram 8
1
0.1
■ Usage Notes
0.01 0.1
1
10
100
Package shall be overheated and dangerous for overcurrent. This device should be used only to the secondary circuit. Package will be damaged for added overpower. This device is not electrical fuse legally. Please draw a clear line between electrical fuse from this device.
Cutoff current (A)
Note) The part number in the parenthesis shows conventional part number.
Publication date: June 2002 SQB00017AED
4.1±0.2
Sharp cutoff characteristics and low voltage drop Flame retardant package and low heat generation. The package is molded with high dimensional accuracy.
R 0.9 R 0.7
2.0±0.2
4.5±0.1
■ Features
(1.0)