(TD2410 / TD2425) Zero Cross0.04-25 Amps RMS24-280 Volts RMS3-32 Control - Volts DC
Series T
10-25Amp • 120/240Vac • AC Output
• • • • • •
Zero Voltage Switching Panel Mount 600V Transient Capability In...
Description
Series T
10-25Amp 120/240Vac AC Output
Zero Voltage Switching Panel Mount 600V Transient Capability Internal Snubber DC or AC Control Triac Output
Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Manufactured in CrydomÕ s ISO 9001 Certified facility for optimum product performance and reliability.
www.DataSheet4U.com
MODEL NUMBERS
AC CONTROL D C CONTROL
TA1210 TD1210
TA1225 TD1225
TA2410 TD2410
TA2425 TD2425
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms] Max. Load Current
24-140 10 40 400 120 1.6 1.48 60 8 200
24-140 25 40 400 250 1.6 1.02 260 8 200
24-280 10 40 600 120 1.6 1.48 60 10 200
24-280 25 40 600 250 1.6 1.02 260 10 200
➂ [Arms]
Min. Load Current, [mArms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (R θJC ) [˚C/W] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load
➁
1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS ➀
Control Voltage Range Max. Reverse Voltage Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current
DC CONTROL
3-32 Vdc -32 Vdc 3.0 Vd...