Document
Bulletin PD-21080 08/05
60EPU04PbF 60APU04PbF
www.DataSheet4U.com
Ultrafast Soft Recovery Diode
Features • Ultrafast Recovery • 175°C Operating Junction Temperature • Lead-Free ("PbF" suffix) Benefits • Reduced RFI and EMI • Higher Frequency Operation • Reduced Snubbing • Reduced Parts Count Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not significant portion of the total losses.
trr = 50ns (typ) IF(AV) = 60Amp VR = 400V
Absolute Maximum Ratings Parameters
VR IF(AV) IFSM IFRM TJ, TSTG Cathode to Anode Voltage Continuous Forward Current, TC = 127°C Single Pulse Forward Current, TC = 25°C Maximum Repetitive Forward Current Operating Junction and Storage Temperatures
Max
400 60 600 120 - 55 to 175
Units
V A
°C
Square Wave, 20kHz
Case Styles
60EPU04PbF
60APU04PbF
CATHODE TO BASE 2
CATHODE TO BASE 2
1
3
1 ANODE
3 ANODE
CATHODE
ANODE
TO-247AC (Modified) www.irf.com
TO-247AC 1
60EPU04PbF, 60APU04PbF
Bulletin PD-21080 08/05
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
VBR, Vr Breakdown Voltage, Blocking Voltage Forward Voltage
Min Typ Max Units Test Conditions
400 V V V V µA mA pF nH IR = 100µA IF = 60A IF = 60A, TJ = 175°C IF = 60A, TJ = 125°C VR = V R Rated TJ = 150°C, VR = V R Rated VR = 400V Measured lead to lead 5mm from package body
www.DataSheet4U.com
VF
1.05 1.25 0.87 1.03 0.93 1.10 50 3.5 50 2 -
IR
Reverse Leakage Current
-
CT LS
Junction Capacitance Series Inductance
-
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
t rr Reverse Recovery Time
Min Typ Max Units Test Conditions
50 85 145 8.8 15.4 375 1120 60 nC A ns IF = 1A, diF/dt = 200A/µs, VR = 30V TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C IF = 60A VR = 200V diF /dt = 200A/µs
IRRM
Peak Recovery Current
-
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
RthJC RthCS Wt Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink Weight 0.2 5.5 0.2 T Mounting Torque Marking Device
Mounting Surface, Flat, Smooth and Greased
Min
Typ
Max
0.70
Units
K/W
g (oz) 2.4 (20) N*m (lbf.in)
1.2 (10)
60EPU04, 60APU04
2
www.irf.com
60EPU04PbF, 60APU04PbF
Bulletin PD-21080 08/05
1000
Reverse Current - I R (µA)
1000
T J = 175˚C
100
125˚C
10 1 0.1 0.01 0.001
www.DataSheet4U.com
25˚C
Instantaneous Forward Current - I F (A)
100
T = 175˚C J T = 125˚C J T = 25˚C J
0
100
200
300
400
Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
1000
Junction Capacitance - C T (pF)
10
T J = 25˚C
100
1 0 0.5 1 1.5 2 2.5
Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics
10 1 10 10.