Document
WT 160 Photoelectric Proximity Switch, Background Suppression, Red Light -- DC
Scanning distance 4 . . . 55 mm
Photoelectric proximity switch Dimensional drawing 11 WT 160 . . .1. 1 2 9.45
38
4.2 3.3
■ Horizontal and vertical models ■ Focussed scanner
9 7.4
23
ø4.2
3
9.45
ø4.2
3
www.DataSheet4U.com
Setting options All types 1 2 3 4 5 Optics center, receiver Optics center, transmitter Plug M 8 or connection cable Sensitivity control Light/dark rotary switch: L = light switching D = dark switching 6 Orange LED indicator (Status output) 7 Green LED signal strength indicator (Operating reserve)
D 7
L
4 5 6
C R s V
Accessories Cable receptacles Mounting bracket (included)
Connection type WT 160-E112 WT 160-E122 WT 160-F112 WT 160-F122 WT 160-E310 WT 160-E320 WT 160-F310 WT 160-F320 WT 160-E410 WT 160-E420 WT 160-F410 WT 160-F420
3 x 0.2 mm2
brn blu blk
3 pin, M 8
brn blu blk
4 pin, M 8
L+ M Q
1 3 4
L+ M Q
brn blu blk wht
1 3 4 2
10
2
11.5 7.5
1
38
15.4 8.1
with background suppression and great sensitivity ■ Contamination control with green LED indicator and contamination control output
10
15.4 8.1
WT 160 . . . 2.
3
11
23
L+ M Q NC
NC = not connected
2
SENSICK
WT 160
Specifications Housing shape Scanning distance, typ. max. Operating scanning distance Background suppression Adjustable sensitivity Light source2), light type Light spot diameter Transmitter dispersion angle Supply voltage VS Residual ripple4) Current consumption5) Switching outputs Horizontal Vertical 4 ... 55 mm 1) 8 ... 50 mm1) From approx. 100 mm Potentiometer, 2 rotations w. scaling 270° LED, red light Approx. 3 mm at 25 mm distance Focussed, focus 25 mm DC 10 ... 30 V 3) ± 10 % ) 25 mA PNP, open collector: Q NPN, open collector: Q 100 mA Light/dark switching per rotary switch ) 0.5 ms / 1000/s PVC, 2 m 8); 3 x 0.2 mm2, ø 4.2 mm 3 pin, M 8 4 pin, M 8 WT 160F112 F310 F410 E112 E310 E410 F122 F320 F420 E122 E320 E420
www.DataSheet4U.com
Output current IA max. Light receiver, switching type Response time6)/Max. switching frequ.7) Connection type: connection cable plug plug VDE protection class9) Protection circuits10) Enclosure rating Ambient temperature Weight Housing material
V
A, B, C, D IP 67 Operation – 25 ... + 55 °C Storage – 40 ... + 70 °C With connection cable approx. 60 g With plug approx. 20 g Housing: PBT; optics: PMMA
1) Scanned material with 90 % reflectance (with reference to standard white according to DIN 5033) 2) Average service life 100,000 h at TU = + 25 °C
3) Limit values 4) May not exceed or fall short of VS tolerances 5) Without load
16) Signal operating time with ohmic load 17) With light/dark ratio 1:1 08) Do not bend connection cable below 0 °C 09) Rated voltage DC 50 V
10) A = VS connections reverse-polarity protected B = Inputs and outputs reverse-po larity protected C = Interference pulse suppression D = Outputs overload and shortcircuit protected
Scanning distance
Ordering information Type WT 160-F112 WT 160-F310 WT 160-F410 WT 160-F122 WT 160-F320 WT 160-F420 WT 160-E112 WT 160-E310 WT 160-E410 WT 160-E122 WT 160-E320 2 3 WT 160-E420 Order no. 6 022 783 6 022 787 6 022 788 6 022 785 6 022 789 6 022 790 6 022 775 6 022 779 6 022 780 6 022 777 6 022 781 6 022 782
1 2 3
4 8 6 8 8 10 30 35 40 45
50 55
100
0 (mm) 10
20
30
40
50
60
■ Operating scanning distance ■ Typ. max. scanning distance
1 Scanning range on white, 90 % reflectance 2 Scanning range on gray, 18 % reflectance 3 Scanning range on black, 6 % reflectance
1
10
Operating reserve
1 0 (mm) Scanning range 50
Operating range
SENSICK
3
WT 160 Photoelectric Proximity Switch, Energetic, Red Light -- DC
Scanning distance 0 . . . 900 mm
Photoelectric proximity switch Dimensional drawing 11 WT 160 . . . 7. 1 2 9.45
38
4.2 3.3
■ Horizontal and vertical models ■ Energetic scanner for
9 7.4
23
ø4.2
3
9.45
ø4.2
3
www.DataSheet4U.com
Setting options All types 1 2 3 4 5 Optics center, receiver Optics center, transmitter Plug M 8 or connection cable Sensitivity control Light/dark rotary switch: L = light switching D = dark switching 6 Orange LED indicator (Status output) 7 Green LED signal strength indicator (Operating reserve)
D 7
L
4 5 6
C R s V
Connection type WT 160-E172 WT 160-E182 WT 160-F172 WT 160-F182 WT 160-E370 WT 160-E380 WT 160-F370 WT 160-F380 WT 160-E470 WT 160-E480 WT 160-F470 WT 160-F480
Accessories Cable receptacles Mounting bracket (included)
3 x 0.2 mm2
brn blu blk
3 pin, M 8
brn blu blk
4 pin, M 8
L+ M Q
1 3 4
L+ M Q
brn blu blk wht
1 3 4 2
10
2
11.5 7.4
1
38
15.4 8.1
standard applications ■ Contamination control with green LED indicator and contamination control output
10
15.4 8.1
WT 160 . . . 8.
3
11
23
L+ M Q NC
NC = not connected
4
SENSICK
WT 160
Specifications Housing shape Scanning distance, typ. max. Operating scanning distance Adjustable sensitivity Light source2), light type Light spot diameter Transmitter dispersion angle Supply voltage VS Res.