Document
SBU60 SERIES
63W Open Frame Switching Power Supplies For I.T.E.
Description:
The SBU60 series of compact, open frame constructed, AC/DC switching mode power supplies provide 63 Watts of continuous output power . They are ideally suited for use in CRT terminals, disc drive systems, microprocess or based systems, portable equipments and many other applications, all models are designed to meet the safety requirements of UL1950/EN60950 requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz Internal EMI filter Single to Quad Output Input connector mates with Molex housing 09-50-3051 and Molex 2878 series crimp terminal www.DataSheet4U.com Output connector mates with Molex housing 09-50-3061 (or 09-50-3081) and Molex 2878 series crimp terminal Output Voltage Available From 3 VDC Thru 50 VDC Input Surge Current, Over Voltage and Over Load protection Size: 3"x5"x1.09" Class I Insulation Two Years Warranty
Safety Approvals :
Electrical Characteristics:
Sym.
Vin Fin Wo Vo Io Iil Iih Irl Irh Eff REG-i REG-o OVP OCP Ttr Thold Ts Vrn Ilk Tc
C
Test Conditions
US
Testing & Certification
ITS
Bauart gepruft
CB
Max. Unit
VAC Hz W V A A A A A % % % % % mS mS S % mA %/ c
Parameter
Input Voltage Input Frequency Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) Low Line Inrush Current High Line Inrush Current
Min.
Typ.
Vin=90 to 264VAC
Efficiency Vin=230VAC 70 80 Line Regulation 0.5 Load Regulation 3 Over Voltage Protection 112 Over Current Protection 110 Transient Response Io=Full Load to Half Load, Vin=100VAC Hold-Up Time Io=Full Load, Vin=100VAC 18 20 Start Up Time Io=Full Load, Vin=100VAC 0.3 1 Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC 1 Safety Ground Leakage Current Io=Full Load, Vin=240VAC 0.4 Temperature Coefficient All output -0.04
Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full Load, Io=Full Load Vin=230VAC
Vin=115VAC Vin=230 VAC 25 c, Cool start, 25 c, Cool start,
90 264 47 63 0 63 See rating chart See rating chart 1.6 1.0 12 26 15 30 88 1 6 132 150 4 2 2 0.45 0.04
Environmental :
Sym.
Toper Tstg Hr Pd
Parameter
Test Conditions
Min.
0 -40 5
Typ.
Max.
70 85 95
Unit
c c
Operating Temperature Storage Temperature Relative Humidity Derate linearly from 100% load at 40 c to 50% load at 70 c
%
Safety Specifications:
Sym. Parameter Test Conditions
Primary to secondary Primary to ground Test Voltage = 500VDC Vin=220VAC Vin=110VAC
Min.
4242 2121 50 B B
Typ. Max.
Unit
VDC VDC
Dielectric Withstanding Voltage Vps for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to ground Ri Isolation Resistance CISPR EMI requirements for CISPR-22 FCC EMI requirements for FCC PART-15
M
CLASS CLASS
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
SBU60 SERIES
63W Open Frame Switching Power Supplies For I..