DatasheetsPDF.com

DFP1000 Dataheets PDF



Part Number DFP1000
Manufacturers Artesyn Technologies
Logo Artesyn Technologies
Description Dual output 1000 Watt AC/DC PFC front-end for distributed power architectures
Datasheet DFP1000 DatasheetDFP1000 Datasheet (PDF)

DPF1000 SERIES Dual output • • • • • • • • 1000W front end EN61000-3-2 compliant 11 x 6.0 x 5.0 inch size Hot pluggable N+1 redundancy Full set of status signals EN55022, EN55011 conducted emissions level A UL, VDE and CSA safety approvals www.DataSheet4U.com [ 2 YEAR WARRANTY ] The DPF1000 is a 1000W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual .

  DFP1000   DFP1000



Document
DPF1000 SERIES Dual output • • • • • • • • 1000W front end EN61000-3-2 compliant 11 x 6.0 x 5.0 inch size Hot pluggable N+1 redundancy Full set of status signals EN55022, EN55011 conducted emissions level A UL, VDE and CSA safety approvals www.DataSheet4U.com [ 2 YEAR WARRANTY ] The DPF1000 is a 1000W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual 48V and 5V outputs with a full set of status signals. The DPF1000 is designed for use as a front end in medium power communication applications adopting distributed power architecture. The DPF1000 is fully compliant with EN61000-3-2. Standard features include current sharing and full protection against overvoltage, overload and short circuit. Remote or local system monitoring is possible via a full set of status signals that include fan fail, DC good, power fail, remote inhibit and current monitoring. The DPF1000, with full international safety approval and the CE mark, meets conducted emissions EN55022 level A. The DPF1000 can be used in conjunction with our complete range of 3 to 200W DC/DC converters to fully configure a distributed power system. SPECIFICATION OUTPUT SPECIFICATIONS Voltage set point Total regulation (Full load to no load) Rise time Transient response All specifications are typical at nominal input, full load at 25°C unless otherwise stated EMC CHARACTERISTICS -48V ±0.1V @ 10A Radiated noise Conducted noise EN55022/11, FCC part 15 EN55022/11 FCC part 15 Harmonic current emm. EN61000-3-2 Electrical fast EN61000-4-4 transients/bursts Surge susceptibility EN61000-4-5 GENERAL SPECIFICATIONS Hold-up time Efficiency 110VAC, 60Hz 110VAC @ 1kW Input/output Input/chassis 20ms @ 1000W 77% min. 3000VAC 1500VAC 200kHz VDE0805, EN60950, IEC950 UL1950, BABT CSA C22.2 No. 950 4.3kg (9.5Ibs) MIL-HDBK-217F @ 25°C full load 80,000 hours Level A Level A Level A Compliant Level 3 Level 3 Main output ±5.0% Auxiliary output, 5V, 0.5A max. ±5.0% At turn-on Main output 75% to 100% step at 0.1A/µs Main output latching 1.0s, max. 5.0% max. dev., 1ms recovery 1.0V pk-pk, -57V to -60V min. 1200W Yes ±10% sharing 0.1V/A droop 1/3L to FL Ripple and noise (20MHz) Overvoltage protection Output power limit Short circuit protection Current sharing Isolation voltage Switching frequency Approvals and standards Weight INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Input surge Safety ground leakage current Input current Input fuse Power factor Notes 1 3 orthogonal axes, random vibration, 10 minute test per axis. 1000W 1200W 90 to 264VAC 108 to 264VAC 47Hz to 63Hz MTBF ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, FL 0°C to +50°C Non-operating -40°C to +70°C 50°C to 70°C Derate linearly ambient to 50% at +70°C Built-in fan Operating Operating Non-operating 5Hz to 500Hz MIL-STD-810E 5% to 85% RH 10,000 feet ma.


SKEA5 DFP1000 DFP14


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)