(VRE105 / VRE107) Precision Reference Supplies
VRE105/107
Precision Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-40...
Description
VRE105/107
Precision Reference Supplies
THALER CORPORATION 2015 N. FORBES BOULEVARD TUCSON, AZ. 85745 (520) 882-4000
FEATURES
www.DataSheet4U.com
APPLICATIONS
PRECISION A/D and D/A CONVERTERS TRANSDUCER EXCITATION ACCURATE COMPARATOR THRESHOLD REFERENCE HIGH RESOLUTION SERVO SYSTEMS DIGITAL VOLTMETERS HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS
VERY HIGH ACCURACY: 5.000 V ±0.4 mV EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ. EXCELLENT LINE REGULATION: 6 ppm/V Typ. WIDE SUPPLY RANGE: ±13.5 V to ±22.0 V HERMETIC 14-PIN CERAMIC DIP MILITARY PROCESSING OPTION
DESCRIPTION
VRE105 Series Precision Voltage References provide ultrastable +5.000 V (VRE105) and ±5.000 V (VRE107) outputs with ±0.4 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range. This impovement in accuracy is made possible by a unique, proprietary multipoint laser compensation technique developed by Thaler Corporation. Significant improvements have been made in other performance parameters as well, including initial accuracy, warm-up drift, line regulation, and long-term stability, making the VRE105 series the most accurate and stable 5V references available.
SELECTION GUIDE
Type VRE105C VRE105CA VRE105M VRE105MA
VRE107C VRE107CA VRE107M VRE107MA
Output +5V +5V +5V +5V
±5V ±5V ±5V ±5V
Temperature Max. Volt Operating Range Deviation -25°C to +85°C 0.4mV -25°C to +85°C 0.2mV -...
Similar Datasheet