Attenuator and Power Amplifier
F E AT U R E S 1 0 0 - 400 MHz 18 dB Gain ±5.0 dB Flatness Input Can Be Terminated Limiter for Amplifier Protection 24 P...
Description
F E AT U R E S 1 0 0 - 400 MHz 18 dB Gain ±5.0 dB Flatness Input Can Be Terminated Limiter for Amplifier Protection 24 Pin Surface Mount Package
MODEL NO. DX090 7
Attenuator and Power Amplifier
HDI
www.DataSheet4U.com
1.560 1.36
PART IDENTIFICATION
GND 24 23
22
21
20
19
18
17
16
GND 15
D1 14
D2 13
.20 .100 TYP .040 TYP .015 (FLANGE)
THRU ISO
DRIVER LOGIC THRU 40 dB 20 dB 20 dB
24
13
.375 TYP .60 TYP
1 12
.77
SWITCH SP4T 40 dB
SWITCH SP4T
LIMITER AMP
50 Ω
50 Ω
.100 TYP 1.100 CONTRASTING COLOR BEAD
.053 R TYP .015 ±.002 TYP .010 ±.002 TYP (LEAD)
1 2 3 4 8 9 11 12 5 6 7 10 RF GND GND GND +10V -12V +5V GND GND GND GND RF INPUT OUTPUT
.xx = .02 .xxx = .010
GUARANTEED PERFORM A NCE
Parameter
Operating Frequency DC Current
Min Typ Max Units
100 100 50 50 TTL
High Low
Conditions
At +10 VDC Supply At +5 VDC Supply At -12 VDC Supply 2 Line VIH = +2.7V VIL = +0.5V
400
MHz mA mA mA µA µA dB dB dB dB dB dB dB
Control Type Control Current Insertion Gain
±40 ±40 18 ±0.5 4.5 40 20 0 ±1.0 2.5/1 50 200 40
Insertion Flatness Noise Figure
Isolation Attenuation
When Input Terminated 20, 40 Non-Additive
LSB Range Accuracy
VSWR Impedance Switching Speed RF Power
Operate
-10 -55 +25 +20 +85
No Damage
Operating Temperature
OHMS nSec 50% TTL to 90% / 10% RF dBm 1.0 dB Compression dBm °C TA
DA I C O In d u s t r i e s
Rev. N/D / Iss. 1
...
Similar Datasheet