MA2400A/D Series 10 MHz to 50 GHz POWER SENSORS Standard diode sensors MA2472A Diode sensors have greater speed, sensitivity and dynamic range than thermal sensors (see fig. 1). All Anritsu diode sensors use a dual diode architecture that gives improved sensitivity and dynamic range over single diode architectures. The MA2470D Series Power Sensors 90 dB dynamic range is both fast and accurate. Linearity is better than 1.8%, typically < 1.0% through 18 GHz. 100000 MA2470A, Sampling Rate MA247.

  MA24xxD   MA24xxD



Document
MA2400A/D Series 10 MHz to 50 GHz POWER SENSORS Standard diode sensors MA2472A Diode sensors have greater speed, sensitivity and dynamic range than thermal sensors (see fig. 1). All Anritsu diode sensors use a dual diode architecture that gives improved sensitivity and dynamic range over single diode architectures. The MA2470D Series Power Sensors 90 dB dynamic range is both fast and accurate. Linearity is better than 1.8%, typically < 1.0% through 18 GHz. 100000 MA2470A, Sampling Rate MA2470A, Reading Rate 10000 Rdgs/sec www.DataSheet4U.com MA2475A 1000 MA2470A, GPIB Continuous Auto-A veraged Readings 100 10 Traditional Diode Sensor Traditional Thermal Sensor -70 -60 -50 -40 -30 -20 -10 10 20 0 Features • • • • • • • • Anritsu Power Sensors consist of MA247XD Series Standard Diode Power Sensors, MA246XD Series Fast Diode Power Sensors, MA248XD Series Universal Power Sensors, MA244XD Series High Accuracy Power Sensors, MA249XA Series Wideband Power Sensors, and MA2411A Pulse Power Sensor. 10 MHz to 50 GHz range N, K, and V type RF connectors 90 dB dynamic range provides stable power readings to –70 dBm MA244XD Series High Accuracy Power Sensors contain an additional matching circuit to improve return loss performance. MA246XD power sensors have fast 1 milli second rise and fall times needed for CDMA measurements MA248XD Universal sensors measure average power of modulated signals such as W-CDMA, multitone, etc. All Power Sensors contain internal EEPROMs for storage of calibration data as a function of frequency, power, and temperature. This allows the power meter to interpolate and correct readings automatically MA2411A Pulse Power Sensor has a rise time of <18ns needed for pulse radar measurements MA249XA Series Wideband Power Sensors have a video bandwidth of 20 MHz for accurate Peak Measurement on Radar and WLAN. These are also is ideal for Multi Pulse Radar or GPRS measurements. 1 0.1 MA2470D power sensors offer an ideal combination of speed and dynamic range for general purpose power measurements. A single sensor replaces the two sensors that were previously required with sensors limited to 50 dB dynamic range. These sensors can be used with any Anritsu power meter. Fig. 1 Standard Diode Sensors Pin • For further information about these products and more, contact us at 1-800-ANRITSU or visit www.us.anritsu.com 55 MA2400A/D Series 10 MHz to 50 GHz POWER SENSORS High accuracy diode sensors The Anritsu MA2440D series high-accuracy diode sensors have a built in 3 dB attenuator to minimize input SWR thus minimizing measurement uncertainty. They are used where the best measurement accuracy is required over a large dynamic range, for example when measuring amplifiers. High accuracy diode sensors have a dynamic range of 87 dB compared to the 90 dB of standard diode sensors. These sensors can be used with any Anritsu power meter. The MA2460D fast diode sensors from Anritsu have a rise time of 0.6 µs. This, together with a sens.


MA24xxA MA24xxD FMA219


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)