DatasheetsPDF.com

HIS-07 Dataheets PDF



Part Number HIS-07
Manufacturers Hanwei
Logo Hanwei
Description Ionization Smoke Chamber
Datasheet HIS-07 DatasheetHIS-07 Datasheet (PDF)

HANWEI ELECTRONICS CO.,LTD Http:www.hwsensor.com www.DataSheet4U.com HIS-07 SPECIFICATIONS 1. SCOPE: This specification sheet is for ionization smoke chamber model HIS-07 (radiation source0.5microcurie Am-241, 2 chambers with a source, made in compliance with UL 217, EN-54-7) for applications to smoke detectors. 2. Radiation source: Nuclide ; americium 241 Radioactivity;Ave.33.3 KBq. =0.9μ CI(29K~37KBq) 3.Operational conditions: Power supply; DC9V Operational ambient conditions; Temperature.

  HIS-07   HIS-07


Document
HANWEI ELECTRONICS CO.,LTD Http:www.hwsensor.com www.DataSheet4U.com HIS-07 SPECIFICATIONS 1. SCOPE: This specification sheet is for ionization smoke chamber model HIS-07 (radiation source0.5microcurie Am-241, 2 chambers with a source, made in compliance with UL 217, EN-54-7) for applications to smoke detectors. 2. Radiation source: Nuclide ; americium 241 Radioactivity;Ave.33.3 KBq. =0.9μ CI(29K~37KBq) 3.Operational conditions: Power supply; DC9V Operational ambient conditions; Temperature 0--50℃ Humidity less than condensation) 4.Maximum ratings: Supply voltage; DC Operation; Storage; 95 (No dew 24V Temperature -10…+60℃ Humidity less than 95% Temperature -25…+80℃ Humidity less than 95% 6.Shape,dimensions, weight; Shape; As per attached drawing Dimensions; 22.0×Ф 42mm Weight; 12g. 7.Ratings: Items Supply voltage Current consumption Output voltage Sensitivity Test conditions; at 25℃,60% RH specifications DC 9V 27±3pA 5.6±0.4 V in clean air 0.6 ± 0.1 V at 2%/foot of smoke (Tested according to UL 217) 8.Characteristics: 8-1.Sensitivity characteristics Table 1 Smoke concentration(%/foot) 0 1 2 3 4 5 TEL:86-371-67169070 67169080 Test conditions ;at 25℃,60% RH output Variation (△V) 5.6±0.4 5.3±0.5 5.0±0.5 4.7±0.5 4.4±0.5 4.2±0.5 FAX:86 371 67169090 0 0.3±0.1 0.6±0.1 0.9±0.2 1.2±0.2 1.4±0.2 E-mail: [email protected] HANWEI ELECTRONICS CO.,LTD Http:www.hwsensor.com www.DataSheet4U.com Gray smoke test according to UL 217 Air velocity;0.16m/sec. 8-2. Supply voltage dependency Table 2 Supply voltage(V) 6 9 12 15 18 Test conditions ;at 25℃,60% RH Output voltage(V) 3.3±0.3 5.6±0.4 8.0±0.7 10.0±0.85 13.0±1.0 8-3 Temperature & Humidity dependency Table 3 Temperature dependency Temperature(℃) 0 25 50 Table 3 Humidity dependency Humidity(%C) 30 60 90 9.Durability tests; 9-1.Heat resistance test Test method At +80 ℃ ± 5 ℃ for 72 hrs. Without electrified 9-2. Low temperature resistance Test method At -30℃±5 ℃ for 72 hrs . without electrified 9-3.High humidity resistance Test method At +40 ℃± 5 ℃ & 85 ± 5% RH for 72 hrs . without electrified Output(V) 5.15±0.4 5.6±0.4 5.85±0.4 Output(V) 5.75±0.5 5.6±0.4 5.45±0.4 (Temperature; 25℃) criteria To maintain the characteristics shown in Heading No.8 after test .To show neither deforming, nor discoloring, nor cracks . criteria To maintain the characteristics shown in Heading No.8 after test .To show neither deforming, nor discoloring, nor cracks. criteria To maintain the characteristics shown in Heading No.8 after test .To show neither deforming, nor discoloring, nor cracks. 9-4.Vibration test Test method Vibrated with amplitude of 0.25mm at every 5Hz from 10 — 35Hz for 15 min . with sympathetic vibration. If no sympathetic vibration occurs, to be vibrated at 35Hz for 4 hour . 9-5.Impact test Test method Dropped from a height of 1m on to a TEL:86-371-67169070 67169080 Criteria To maintain the characteristics shown in Heading No.8 after test. To show neither deforming , nor discoloring ,nor cracks . criteria To maintain the characteristics shown in E-mail: [email protected] FAX:86 371 67169090 HANWEI ELECTRONICS CO.,LTD Http:www.hwsensor.com wooden plate with 3 different directions . www.DataSheet4U.com Heading No.8 after test .To show neither deforming , nor discoloring , nor cracks . 10. Remarks 10.1 Output voltage is to be measured using an electrometer with more than 1014 of impedance or an exclusively designed measuring circuit with Ics . Normal testers with around 100MΩ impedance would be insufficient for measurement . 10.2 Upon assembling detectors ,attention is to be paid not to let a soldering flux get inside smoke chambers .If inside of the chambers is contaminated ,cleaning or washing is necessary . 10.3The output lead wire of a chamber and an input terminal of a circuit must be connected in air to keep the connected point away from the surface of a PC board(usually a teflon pin is used to support the connected point) .Because of the resistance level of paper phenol PC boards , current leakage will occur on to the PC board . This will prevent to read correct outputs . 10.4 The connected point of the lead wire and the input terminal of an FET or an IC must be protected from humidity using a silicon resin or the like so that current leakage from the packages will be minimized . 10.5 Because of the necessity of reading a tiny current put out from the chamber ,this sensor must be electrically shielded to minimize noises from the outside .As the most sensitive part to noises is the connected part of the lead wire and the input the terminal of a circuit ,this part must definitely be shielded . TEL:86-371-67169070 67169080 FAX:86 371 67169090 E-mail: [email protected] .


IXFN102N30P HIS-07 HIS-07


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)