Surge Arrester 2-Electrode-Arrester
www.DataSheet4U.com
Surge Arrester 2-Electrode-Arrester
V10-H30X Ordering code: B88069X4330C251
DC spark-over voltage...
Description
www.DataSheet4U.com
Surge Arrester 2-Electrode-Arrester
V10-H30X Ordering code: B88069X4330C251
DC spark-over voltage 1) 2) Impulse spark-over voltage at 1 kV/µs - for 99 % of measured values - typical values of distribution Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) Nominal alternating discharge current (50 Hz, 1 s) Alternating discharge current (50 Hz, 9 cycles) Insulation resistance at 100 Vdc Capacitance at 1 MHz Arc voltage at 1 A Glow to arc transition current Glow voltage Weight Operation and storage temperature Climatic category (IEC 60068-1) Marking, black
3000 ± 25 < 5000 < 4500 20 25 20 100 > 10 < 1.5 ~ 30 ~1 ~ 200 ~9 -40 ...+90 40/.90/.21 3000 YY O
3000 YY O - Nominal voltage - Year of production - Non radioactive
V % V V kA kA A A GΩ pF V A V g °C
1) 2)
At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM Page 1 of 2
Issue 03, 26.04.2002
www.DataSheet4U.com
Surge Arrester 2-Electrode-Arrester
V10-H30X Ordering code: B88069X4330C251
Not to scale Dimensions in mm Non controlled document
© EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommende...
Similar Datasheet