Document
Plug-in relays Micro ISO relays
Micro power relay A
www.DataSheet4U.com
Powertrain Systems Features – Limiting continuous currents 25/15 A at the NO contact/ NC contact – Pin assignment to ISO 7588 part 3 – Positions of quick connect terminals to ISO 7588 part 3 – Compact dimensions Typical applications – Heaters (seat, front/rear windows) – Motors (fan, pump, wiper) – Valves, lifting magnets, interlocks – Headlights, lighting
Chassis Systems
Safety
Security
Body
Driver Information
Convenience
Car Industry
Truck Industry
Other Industry
74_3d01
Design Dustproof; protection class IP 54 to IEC 60 529 (EN 60 529) Optional cover markings; color-coded Weight Approx. 0.5 - 0.7 oz. (16 - 20 g) depending on contact Nominal voltage 12 V or 24 V, VFM (see page 82) also 6 V; other nominal voltages available on request Terminals Quick connect terminals similar to ISO 8092-1 Coil and break contact 4.8 x 0.8 mm, other load terminals 6.3 x 0.8 mm; surfaces tin-plated Accessories Connectors see page 180
Special models on request – 1 component (diode or varistor) parallel to the coil – Special labels – Special cover shapes Conditions All parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions unless otherwise noted: 23 °C ambient temperature, 20-50% RH, 29.5 ± 1.0" Hg (998.9 ±33.9 hPa).
75
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Plug-in relays Micro ISO relays
Micro power relay A
www.DataSheet4U.com Dimension drawing
.898 ±.008 (22.8 ±0.2) .602 ±.008 (15.3 ±0.2)
.992 ±.008 (25.2 ±0.2)
.949 ±.008 (24.1 ±0.2) Measurement reference plane
.441 ±.012 (11.2 ±0.3)
.189 ±.004 (4.8 ±0.1)
.031 ±.002 (0.8 ±0.05)
.248 ±.004 (6.3 ±0.1)
ECR0585-S
Quick connect terminal similar to ISO 8092-1
View on the terminals (bottom view)
.177 ±.006 (4.5 ±0.15) .453 ±.008 (11.4 ±0.2)
View on the terminals (bottom view)
.354 ±.006 (9 ±0.15)
.301 ±.008 (7.65 ±0.2)
ECR0587-9
.177 ±.006 (4.5 ±0.15)
.236 ±.006 .315 ±.006 (6 ±0.15) (8 ±0.15)
Cover markings View from above (view from above)
Cover markings: Sorting feature Color coding .118 ±.004 (3 ± 0.1) .118 ±.004 (3 ± 0.1)
ECR0588-H
Models with color coded covers on request
76
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Plug-in relays Micro ISO relays
Micro power relay A
www.DataSheet4U.com
Contact data
Typical areas of application Contact configuration Contact material Circuit symbol (see also Pin assignment)
12 V nominal voltage, test voltage 13 VDC
Resistive/inductive loads Make contact/ Changeover contact/ Form A Form C AgNi0.15 Make contact/ Form A Lamp loads Changeover contact/ Form C AgSnO2
Max. switching voltage Max. switching power Max. switching current1) On 2) Off Limiting continuous current at 23 °C at 85 °C Voltage drop (initial) at 10 A Increase in coil temperature at 10 A load Mechanical endurance (without load) Electrical endurance
1) 2) 3)
See load limit curve See load limit curve 90 A 30 A 25 A 15 A NC/NO 20/90 A 15/30 A NC/NO 15/25 A 10/15 A Typ. 20 mV Typ. 5 °C > 106 operations See page 81 120 A3) 30 A 25 A 15 A NC/NO 40/120 A 15/30 A NC/NO 15/25 A 10/15 A
The values apply to a resistive load or inductive load with suitable spark suppression. This current may flow for a maximum of 3 sec for a make/break ratio of 1 : 10. Corresponds to the peak inrush current of a lamp on initial actuation (cold coil filament).
77
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
Plug-in relays Micro ISO relays
Micro power relay A
www.DataSheet4U.com
Contact data
Typical areas of application Contact configuration Contact material Circuit symbol (see also Pin assignment)
24 V nominal voltage, contact gap ≥ 0.6 mm, test voltage 27 VDC
Resistive/inductive loads Make contact/ Changeover contact/ Form A Form C AgNi0.15 Lamp loads Make contact/ Form A AgSnO2
Max. switching voltage Max. switching power Max. switching current1) On 2) Off Limiting continuous current at 23 °C at 85 °C Voltage drop (initial) at 10 A Increase in coil temperature at 10 A load Mechanical endurance (without load) Electrical endurance
1) 2) 3)
40 A 20 A 25 A 15 A
See load limit curve See load limit curve NC/NO 20/40 A 10/20 A NC/NO 15/25 A 10/15 A Typ. 20 mV Typ. 5 °C Typ. 107 operations See page 81
80 A3) 15 A 25 A 15 A
The values apply to a resistive load or inductive load with suitable spark suppression. This current may flow for a maximum of 3 sec for a make/break ratio of 1 : 10. Corresponds to the peak inrush current of a lamp on initial actuation (cold coil filament).
Load limit curve
Load limit curve 1 arc extinguishes during transit time (changeover contact) Load limit curve 2 safe shutdown, no stationary arc (make contact)
Pin assignment 1 make contact/ 1 form A 1 changeover contact/ 1 form C
ECR2186-L
ECR2187-U
Models with diode in parallel to the .