(UL1xxx) PVC Wire
Single-core
|
UL and CSA cables
LIYW UL 1015/CSA TEW LIYW UL 1028/CSA TEW www.DataSheet4U.com LIYW UL 1569/CSA T1
PV...
Description
Single-core
|
UL and CSA cables
LIYW UL 1015/CSA TEW LIYW UL 1028/CSA TEW www.DataSheet4U.com LIYW UL 1569/CSA T1
PVC wire according to UL 758 AWM / CSA C22.2 Rating
+105 °C UL +105 °C CSA
Construction / Materials Conductor Soft-annealed electrolytic copper CU-ETP1, bare or tinned, according to DIN EN 13602, conductor construction according to UL/CSA Insulation PVC compound compliant with UL/CSA LIYW UL 1015/CSA TEW LIYW UL 1028/CSA TEW LIYW UL 1569/CSA T1 nominal voltage max. 600 V AC 600 V AC 300 V AC
Standards Appliance Wiring Material UL 758 AWM (USA) Radio Circuit Wire CSA C22.2 (Canada) Authorization number UL 47543/CSA LL 34123
Nominal cross section
Conductor construction No. of wires × wire Ø
Diameter of conductor
Outer diameter
nom. mm2 AWG mm2 AWG mm
nom. mm
Electrical resistance at 20 °C plain max. Ω/km
Weight
approx. kg/km
LIYW UL 1015/CSA TEW Minimum wall thickness 0.8 mm / 30 mils 0.14 26 7×0.160 7/34 0.5 2.1 1.0 18 19×0.254 19/30 1.3 2.85 0.82 18 16×0.254 16/30 1.2 2.8 2.1 14 41×0.254 41/30 1.8 3.6 5.3 10 105×0.254 105/30 3.0 4.8 LIYW UL 1028/CSA TEW Minimum wall thickness 1.2 mm / 45 mils 0.35 22 7×0.254 7/30 0.75 3.3 0.82 18 16×0.254 16/30 1.2 3.7 2.1 14 41×0.254 41/30 1.8 4.5 5.3 10 105×0.254 105/30 3. 0 5.6 8.2 8 168×0.254 168/30 3.8 6.5 LIYW UL 1569/CSA T1 Minimum wall thickness 0.4 mm / 15 mils 0.06 30 7×0.102 7/38 0.3 0.09 28 7×0.127 7/36 0.4 0.22 24 7×0.203 7/32 0.6 22 12×0.203 12/32 0.8 0.38 20 19×0.195 19/32 1.0 0.56 ...