(SLA-xx) Power Relay
Relays for advanced technology
ULTRA-MINIATURE PC BOARD TYPE POWER REL AY
SL A-REL AY
www.datasheet4u.com
UL,C-UL Fi...
Description
Relays for advanced technology
ULTRA-MINIATURE PC BOARD TYPE POWER REL AY
SL A-REL AY
www.datasheet4u.com
UL,C-UL File No.:E190598 TUV File No.:R50032402 CQC File No.:CQC02001002109 High switching capacity-30A for 1 Form A(B). Sealed type available. ●Initial breakdown voltage 5KV available.
● ●
SPECIFICATIONS
Contact
Contact material Contact resistance
(By voltage drop 1A 6VDC) 1c Silver alloy 50 mΩMax.
Characteristics
Operate time Release time Operating humidity
N.C: 15msec. Max. 10msec. Max. 45~85% RH 1,500VAC (50/60Hz) for 1 min. 5,000VAC (50/60Hz) for 1 min.
Arrangement UL/C-UL rating Resistance load (cosφ=1) Inductive load
(Cosφ=0.75~0.8)
1a,1b N.O:
30A
240VAC
20A
240VAC
10A
240VAC
Initial breakdown voltage
Between contact and coil Between open contacts
1,500VAC (50/60Hz) for 1 min.
15A
240VAC
10A 1-1/2HP 3/4HP 20A 20A
240VAC 240VAC 125VAC 240VAC 250VAC 20A
10A
240VAC
Insulation resistance Ambient temperature Shock resistance Vibration resistance Functional Destructive Functional Destructive
1,000MΩ Min.(500VDC) -40℃ ~+85℃ 010G Min. 100G Min. 10 TO 55 Hz at double Amplitude of 1.5mm 10 TO 55 Hz at double Amplitude of 1.5mm Open type Approx. 20g Approx. 25g
1-1/2HP C240VAC 1-3/4HPV 120VAC 1a: 30A 1b: 15A 240VAC 240VAC 250VAC
1/2HP 0 240VAC 1/4HP 10A 10A 125VAC 240VAC 250VAC
Motor load TUV rating CQC rating Max.switching current Max.switching power Max.switching voltage Expected Life
(min.ope)
30A 30A
10A 2,400VA
7,200VA
4,800VA 250VAC 1X10
...
Similar Datasheet