Feature ANDPSI056ET1S-HB; Displays ANDpSi056ET1S-HB www.datasheet4u.com 5.61” WSVGA Color p-Si TFT LCD Module The ANDpSi056ET.
Manufacture Purdy Electronics Corporation
Datasheet
Download ANDPSI056ET1S-HB Datasheet





Purdy Electronics Corporation ANDPSI056ET1S-HB
Displays
www.datasheet4u.com
ANDpSi056ET1S-HB
5.61” WSVGA Color p-Si TFT
LCD Module
The ANDpSi056ET1S-HB is 1024 x 600 Color TFT display that
utilizes new poly-silicon (p-Si) technology to provide a brighter,
thinner and lighter display with high-resolution. The p-Si TFT
technology allows the row and column LCD drivers to be
fabricated directly on the LCD glass. This eliminates the need for
discrete TAB drivers and also reduces the thickness, weight and
overall size of the display. The 5.6” WSVGA resolution
expands applications in mini-notebook PC’s.
Features
• RoHS Compliant
• High Luminance - 250 nits
• Single CCFL, Sidelight type
• Replaceable structure of lamp units
• WSVGA (1024 x 600 pixels color display)
• LVDS display data interface
• Applications: hand-held mobile devices
Mechanical Characteristics
Item
Outline
Dimensions
Number of
Pixels
Active Area
Pixel Pitch
Weight (approx.)
Backlight
Specification
141.8(W) x 84.4 (H) x 7.5max(D)
1024(W) x 600(H)
122.88 (W) x 72(H)
0.120(W) x 0.120(H)
85
Single CCFL, Sidelight type
Unit
mm
pixels
mm
mm
gram
Absolute Maximum Ratings
Item
Symbol Min. Max. Unit
Supply Voltage
VDD -0.3 +4.0
V
Input Signal Voltage
VIN
-0.3 VDD +
0.3
V
Operating Ambient Temperature TOP 0 50
°C
Operating Ambient Humidity
HOP 10 90 %(RH)
Storage Temperature
TSTG -20 +60
°C
Storage Humidity
HSTG 10 90 %(RH)
Operating Temperature for
Panel
0 +60 °C
Electrical Characteristics (Ta = 25°C)
Item
Supply Voltage 1)
IFL=4.0mA(rms)
FL Start Voltage
(Ta = 0°C)
Common Mode
Input Voltage 2)
Differential Input
High Threshold
Differential Input
Low Threshold
Current
Consumption
Pwr Consumption
IFL=4.0mA(rms)
Symbol Min.
VDD 3.0
VFL
Typ.
3.3
500
VSFL (1000) –
VCM 0.5 1.2
VTH _
_
VTL -100
*1(IDD)
*2(IFL)
_
(200)
5.0
P – 2.66
Max.
3.6
Unit
V
V(rms)
(1500) V(rms)
1.75 V
100 mV
_ mV
– mA
5.5 mA(rms)
–W
*1) The module should be always operated within these ranges. The
"Typ." shows the recommendable value.
*2) Recommended transmitter:
Optical Characteristics (Ta = 25°C)
Item
Min. Typ. Max. Unit
Contrast Ratio (CR)
(100) (300) –
Response Time
Luminance (L)
IFL=4.0mA(rms)
(tON + tOFF)
––
120 250
50 ms
cd/m2
Product specifications contained herein may be changed without prior notice.
It is therefore advisable to contact Purdy Electronics before proceeding with the design of equipment incorporating this product.
9/26/07
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8216 • Fax: 408.733.1287 • sales@purdyelectronics.com
www.purdyelectronics.com
1



Purdy Electronics Corporation ANDPSI056ET1S-HB
Displays
Dimensional Outline
Front View
www.datasheet4u.com
ANDpSi056ET1S-HB
Unit: mm
Standard Tolerance: 0.5mm
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
2
Tel: 408.523.8216 • Fax: 408.733.1287 • sales@purdyelectronics.com
9/26/07
www.purdyelectronics.com



Purdy Electronics Corporation ANDPSI056ET1S-HB
Displays
ANDpSi056ET1S-HB
Timing Specifications (see Notes below)
Item
Horizontal Scanning Term
H-sync Pulse Width
www.datasheet4u.com
Horizontal Front Porch
Horizontal Back Porch
Horizontal Data Sync Period
Horizontal Display Term
Frame Period
V-sync Pulse Width
V-sync Set up Time (to H-sync)
V-sync Hold Time
Vertical Front Porch
Vertical Back Porch
Vertical Data Sync Period
Vertical Display Time
Clock Period
Symbol
th
thw
thfp
thbp
thds
thd
tv
tvw
tvsu
tvhd
tvfp
tvbp
tvds
tvd
tc
Min
1334 x tc
8 x tc
4 x tc
24 x tc
32 x tc
1024 x tc
778 x th
2 x th
8 x tc
8 x tc
1 x th
2 x th
8 x th
600 x th
15.0
Typ
1344 x tc
136 x tc
24 x tc
160 x tc
296 x tc
1024 x tc
806 x th
6 x th
3 x th
29 x th
35 x th
600 x th
15.38
Max
1024 x tc
860 x th
600 x th
Unit
clock
clock
clock
clock
clock
clock
line
line
clock
clock
line
line
line
line
ns
Notes:
Refer to “Timing Chart” below. If DE is fixed to “H” or “L” level for certain period while CLK is supplied, the panel displays black w/some flicker.
If CLK is fixed to “H” or “L” level for certain period while DE is supplied, the panel may be damaged. Please adjust LCD operating signal timing and FL
driving frequency, to optimize the display quality. There is a possibility that flicker is observed by the interference of LCD operating signal timing and
FL driving condition (especially driving frequency), even if the condition satisfies above timing specifications and recommended operating condi-
tions. Do not make tv, th, thbp and tvds fluctuate. If tv, th, thbp and tvds are fluctuate, the panel display black. In case of using the long frame period,
the deterioration of display quality, noise, etc. may be occurred. CLK count of each Horizontal Scanning Time should be always the same. V-Blanking
period should be ‘n’ X “Horizontal Scanning Time”. (n:integer) Frame period should be always the same.
Timing Chart
9/26/07
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8216 • Fax: 408.733.1287 • sales@purdyelectronics.com
www.purdyelectronics.com
3





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)