DatasheetsPDF.com

SR1 Dataheets PDF



Part Number SR1
Manufacturers Schneider
Logo Schneider
Description Relay
Datasheet SR1 DatasheetSR1 Datasheet (PDF)

www.DataSheet4U.com Zelio-Logic Relays SR1 File 8501 CONTENTS Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Overview of Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Ordering Information . . . . . . . . . . . ..

  SR1   SR1



Document
www.DataSheet4U.com Zelio-Logic Relays SR1 File 8501 CONTENTS Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Overview of Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wiring Diagrams and Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Schneider Electric Brands www.DataSheet4U.com Zelio-Logic Relay www.DataSheet4U.com Overview The Zelio-Logic relay is more than a typical relay. It will accept inputs, and has relay outputs like a programmable controller, but can not be connected to a network. Because it has timers, counters and clocks that can be programmed, this product is ideal for applications where a typical relay, timer or time clock isn’t enough, but a PLC is not justified. • The Zelio-Logic relay is designed for use in small automated systems. • It can be used in industrial and commercial applications. • Its small size and ease of programming provides a competitive alternative to traditional relays, timers and counters. • Programming can be done on the relay or by using the Zelio-Soft software on your windows based computer. • Zelio-Logic relays with four outputs will accept a 60 line program. • Zelio-Logic Relays with eight outputs will accept a 80 line program. • Programming in Zelio-Soft can be done in ladder logic, electrical symbols or Zelio symbols. Description 1. Retractable mounting feet 2. Power supply terminals 3. LCD display (4 lines, 12 characters) 4. Input terminals 5. Analog input terminals (0-10 V or 24 Vdc) 6. Delete or Cancellation button 7. Insert a new line button 8. Navigational keys or Input keys in RUN mode 9. Selection or validation button 10. Escape button 11. Slot for memory back-up EEPROM cartridge or cable connection for down loading or uploading of programs. 12. Relay output terminals 13. Marking area Main Zelio-Logic Screen 1. Status of inputs 2. RUN or STOP mode indication 3. Indication of a parameter (day and time is default for relays with a clock) 4. Status of outputs 1 2 1 2 3 4 5 6 7 8 9 10 11 13 12 1 MO : 3 4 The dc relays have a fast input function “FILT”. This function allows faster detection of changes in state of the inputs. This mode should only be used when necessary as it makes the relay inputs more sensitive to interference and contact bounce. A “Fast” or “Slow” choice is available. 3 02/01 © 2001 Schneider Electric All Rights Reserved Zelio-Logic Relay Overview www.DataSheet4U.com Function Electrical Scheme Ladder Language Zelio Relay Symbol Notes N.O. SPSTNO Contact N.C. SPSTNC Ix v 14 I corresponds to the real image of the contact connected to the input of the module. 13 Ix v 22 i (l) corresponds to the reversed image of the contact connected to the input of the module. 21 Standard Coil Qx A2 The coil is energized when the contacts to which it is connected are closed. A1 Latch Coil (Set) A2 S SQ The coil is energized when the contacts to which it is connected are closed. It remains energized when the contacts re-open. A1 Unlatch Coil (Reset) R RQ v ix will work the inverse of Ix. Example: STOP START M A2 The coil is de-energized when the contacts to which it is connected are closed. It remains inactive when the contacts re-open. A1 L1 M1 L1 L2 L2 I1 I2 Q1 Q1 i1 I2 Q1 Q1 OR 4 © 2001 Schneider Electric All Rights Reserved 02/01 Zelio-Logic Relay www.DataSheet4U.com Overview of Functions Eight Time Delay Functions (provided as standard in all relays) Each timer function can be programmed to function in one of the following eight modes: On-Delay On-Delay (with momentary input) Off-Delay One Shot One Shot (when input is removed) Repeat Cycle (with maintained input) Repeat Cycle (with momentary input) Totalizing Timer with Reset Each timer function has a preset time in one of four timing ranges: 00.00 s (1/100 of a second) 000.0 s (1/10 of a second) 00:00 M:S (Minutes: Seconds) 00:00 H:M (Hours: Minutes) Maximum of 99.99 seconds Maximum of 999.9 seconds (16.665 minutes) Maximum of 99:59 Maximum of 99:59 The time setting on each timer can be locked. A password is required to unlock the timer. Eight Counters (provided as standard in all relays) Count up and/or count down. Each counter function can have a preset value of 0000 to 9999. The counter setting on each counter can be locked. A password is required to unlock the counter. For more information on these timers and counters, refer to the User’s Manual #SR1MAN01EN. 5 02/01 © 2001 Schneider Electric All Rights Reserved Zelio-Logic Relay Overview of Functions www.DataSheet4U.com Some Versio.


SR1xxx1BD SR1 ISL5827


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)