1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Application Type Designation Outline Dimensions Absolute Maximum Rating Recommended Line Voltage Range Measuring Circuit Electrical Characteristic Reliability Tests Notes for Use Temperature Humidity Characteristics (for Reference)
HOKURIKU ELECTRIC INDUSTRY CO.,LTD.
1 . A p p l ica t i o n
www.DataSheet4U.com
This specification shall be applied to the relative humidity sensor [HSU-07].
2 . Ty p e D e si g na t i o n
HSU - 07 A 2
Design No. Mark of Contour Mounted Hole Mark Substrate Contour A 18 × 30 mm φ4mm × 1 ---B 18 × 21 mm Number of Output Characteristic Humidity Detection Range Mark 10 ~ 90%RH 06 20 ~ 90%RH 07 Humidity Sensor Unit Type Name
3. Outline Dimensions
18±0. 5 12M A X
5
φ4
7 M AX
1. 6T yp
3. 4 M AX
5 (9)
30±0. 5
① ② ④ ⑤
(2) (2) (4) ※はと する。
③
(4)
11 22 33 12 34
: mm
Mounting of a part is prohibited on the hatched area.
No. 1 2 3
Connector Pin Arrangement Name Mark
Power Source Terminal Output Terminal Vcc Vout
Parts Component Table
Parts No. Name Material and Specification HIS-06 Paper Phenol U L 9 4 V- 0 t = 1 . 6 m m
① ② ③
Humidity Sensor Printed CircuitBoard SMD
Mount Surface
Ground Terminal
GND
④
Connector
CT connector S3B-PH-K-S, 2mm pitch, 3 Pin manufactured by JST
HOKURIKU ELECTRIC INDUSTRY CO.,LTD.
4 . A b so l u t e M a x i m u m R a t i n g s
www.DataSheet4U.com
No. 1 2 3 4 5
Item Rated Voltage Operating Temp. Range Operating Humidity Range Storage Temp. Range Storage Humidity Range
Rated Value DC 0 ~ 7 V -20 ~ +60 ℃ 20 ~ 90 %RH -25 ~ +70 ℃ 0 ~ 90 %RH (Do not let it have dewdrops.)
5. Re c om m e n de d Li n e Vo l ta ge Ra n g e DC:5V +/- 0.25V 6 . Me a su r i n g C i rc u i t
Vcc DC5V Input
Stabilized Power Supply
6 . E l e c t r i c a l C h a ra c t e r i s t i c s
The condition regarding the table below is 25deg.C in temperature and operating voltage 5V. (The one for the output shift caused by the line voltage variation is not included.)
Item Humidity Detection Output (Accuracy) Consumption Current Conditions 40%RH 60%RH Icc ------------60%RH 30 ~ 90 %RH 30%RH⇔90%RH Wind speed 1.2 ㎝/sec. (90% arrival) Min. 1.578
(-5%RH)
Hysteresis Characteristics Humidity Response Characteristics
Humidity Sensor Unit
Vout Humidity Detection Output
47μF
Digital Multi-meter
100k ohm
GND
Typ 1.744 2.220 1.30 +/- 1
Max. 1.888
(+5%RH)
Unit V V mA %RH
minutes
2.120
(-5%RH)
2.318
(+5%RH)
-------
3.5
HOKURIKU ELECTRIC INDUSTRY CO.,LTD.
8 . Re liab i lity Te sts
www.DataSheet4U.com
No. 1
Test Item Drop Test
Test Condition Criteria The sample shall not Drop the test piece one time from the height of 1m in each of X, Y and Z directions onto the lauan have any abnormality in the appearance and the material of 30 mm thickness.
humidity detection output shall be in the electric characteristics of item 7.
2 3 4 5 6
Heat Shock Exposure to High Temperature Exposure to High Humidity Exposure to Low Temperature Load Life
The samples are subjected to 10 cycles of 2 hours’ exposure of each of –25deg.C and +70deg.C (Do not let it have dewdrops.) The samples are exposed to a temp. of +70deg.C for 1000 hrs. The samples are exposed to a temp. of +40deg.C with 95%RH for 1000 hrs. The samples are exposed to a temp. of –25deg.C for 1000 hrs. The samples are subjected to a consecutive electric load in the normal temperature and humidity for 1000 hrs.
The variation of the humidity detection output shall be within +/- 5% against the initial value.
*1)The measurement of the humidity detection output is done after 15 minutes has passed with the advantage way-type precision humidity producing device after the temperature humidity setting. *2)The measurement of the reliability test parts is done after they are left for more than two hours in the normal temperature and the normal humidity.
9. Notes for Use
(1)Do not get the product wet in the water, and do not let it have dewdrops. Characteristics may change permanently. (2)Do not make foreign materials such as a solvent, oil and fat stick to the humidity sensor. It may stop fulfilling normal features. (3)Do not use for medical apparatus (application involving risk of affecting life).
HOKURIKU ELECTRIC INDUSTRY CO.,LTD.
10. Temperature Humidity Characteristics of HSU-07 (for Reference)
www.DataSheet4U.com
Temperature Humidity Characteristics of HSU-07 (for Reference)
H SU -07
3. 0
2. 5
2. 0 V out
1. 5
5deg.C
1. 0
5℃ 25deg.C 25℃ 45deg.C 45℃
0. 5
0. 0 0 10 20 30 40 50 60 H %R 70 80 90 100
.