www.DataSheet4U.com For Reference Only Product Specifications HSU – 07 Series Humidity Sensor Unit HOKURIKU ELECTRIC INDUSTRY CO.,LTD. www.DataSheet4U.com Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Application Type Designation Outline Dimensions Absolute Maximum Rating Recommended Line Voltage Range Measuring Circuit Electrical Characteristic Reliability Tests Notes for Use Temperature Humidity Characteristics (for Reference) HOKURIKU ELECTRIC INDUSTRY CO.,LTD. 1 . A p p l ica t i o n www.Da.

  HSU-07   HSU-07



Document
www.DataSheet4U.com For Reference Only Product Specifications HSU – 07 Series Humidity Sensor Unit HOKURIKU ELECTRIC INDUSTRY CO.,LTD. www.DataSheet4U.com Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Application Type Designation Outline Dimensions Absolute Maximum Rating Recommended Line Voltage Range Measuring Circuit Electrical Characteristic Reliability Tests Notes for Use Temperature Humidity Characteristics (for Reference) HOKURIKU ELECTRIC INDUSTRY CO.,LTD. 1 . A p p l ica t i o n www.DataSheet4U.com This specification shall be applied to the relative humidity sensor [HSU-07]. 2 . Ty p e D e si g na t i o n HSU - 07 A 2 Design No. Mark of Contour Mounted Hole Mark Substrate Contour A 18 × 30 mm φ4mm × 1 ---B 18 × 21 mm Number of Output Characteristic Humidity Detection Range Mark 10 ~ 90%RH 06 20 ~ 90%RH 07 Humidity Sensor Unit Type Name 3. Outline Dimensions 18±0. 5 12M A X 5 φ4 7 M AX 1. 6T yp 3. 4 M AX 5 (9) 30±0. 5 ① ② ④ ⑤ (2) (2) (4) ※はと する。 ③ (4) 11 22 33 12 34 : mm Mounting of a part is prohibited on the hatched area. No. 1 2 3 Connector Pin Arrangement Name Mark Power Source Terminal Output Terminal Vcc Vout Parts Component Table Parts No. Name Material and Specification HIS-06 Paper Phenol U L 9 4 V- 0 t = 1 . 6 m m ① ② ③ Humidity Sensor Printed CircuitBoard SMD Mount Surface Ground Terminal GND ④ Connector CT connector S3B-PH-K-S, 2mm pitch, 3 Pin manufactured by JST HOKURIKU ELECTRIC INDUSTRY CO.,LTD. 4 . A b so l u t e M a x i m u m R a t i n g s www.DataSheet4U.com No. 1 2 3 4 5 Item Rated Voltage Operating Temp. Range Operating Humidity Range Storage Temp. Range Storage Humidity Range Rated Value DC 0 ~ 7 V -20 ~ +60 ℃ 20 ~ 90 %RH -25 ~ +70 ℃ 0 ~ 90 %RH (Do not let it have dewdrops.) 5. Re c om m e n de d Li n e Vo l ta ge Ra n g e DC:5V +/- 0.25V 6 . Me a su r i n g C i rc u i t Vcc DC5V Input Stabilized Power Supply 6 . E l e c t r i c a l C h a ra c t e r i s t i c s The condition regarding the table below is 25deg.C in temperature and operating voltage 5V. (The one for the output shift caused by the line voltage variation is not included.) Item Humidity Detection Output (Accuracy) Consumption Current Conditions 40%RH 60%RH Icc ------------60%RH 30 ~ 90 %RH 30%RH⇔90%RH Wind speed 1.2 ㎝/sec. (90% arrival) Min. 1.578 (-5%RH) Hysteresis Characteristics Humidity Response Characteristics Humidity Sensor Unit Vout Humidity Detection Output 47μF Digital Multi-meter 100k ohm GND Typ 1.744 2.220 1.30 +/- 1 Max. 1.888 (+5%RH) Unit V V mA %RH minutes 2.120 (-5%RH) 2.318 (+5%RH) ------- 3.5 HOKURIKU ELECTRIC INDUSTRY CO.,LTD. 8 . Re liab i lity Te sts www.DataSheet4U.com No. 1 Test Item Drop Test Test Condition Criteria The sample shall not Drop the test piece one time from the height of 1m in each of X, Y and Z directions onto the lauan have any abnormality in the appearance and the material of 30 mm thickness. humidity detection output shall be in the electric characteristics of item 7. 2 3 4 5 6 Heat Shock Exposure to High Temperature Exposure to High Humidity Exposure to Low Temperature Load Life The samples are subjected to 10 cycles of 2 hours’ exposure of each of –25deg.C and +70deg.C (Do not let it have dewdrops.) The samples are exposed to a temp. of +70deg.C for 1000 hrs. The samples are exposed to a temp. of +40deg.C with 95%RH for 1000 hrs. The samples are exposed to a temp. of –25deg.C for 1000 hrs. The samples are subjected to a consecutive electric load in the normal temperature and humidity for 1000 hrs. The variation of the humidity detection output shall be within +/- 5% against the initial value. *1)The measurement of the humidity detection output is done after 15 minutes has passed with the advantage way-type precision humidity producing device after the temperature humidity setting. *2)The measurement of the reliability test parts is done after they are left for more than two hours in the normal temperature and the normal humidity. 9. Notes for Use (1)Do not get the product wet in the water, and do not let it have dewdrops. Characteristics may change permanently. (2)Do not make foreign materials such as a solvent, oil and fat stick to the humidity sensor. It may stop fulfilling normal features. (3)Do not use for medical apparatus (application involving risk of affecting life). HOKURIKU ELECTRIC INDUSTRY CO.,LTD. 10. Temperature Humidity Characteristics of HSU-07 (for Reference) www.DataSheet4U.com Temperature Humidity Characteristics of HSU-07 (for Reference) H SU -07 3. 0 2. 5 2. 0 V out 1. 5 5deg.C 1. 0 5℃ 25deg.C 25℃ 45deg.C 45℃ 0. 5 0. 0 0 10 20 30 40 50 60 H %R 70 80 90 100 .


JRM-12232A HSU-07 MAX17480


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)