Document
www.DataSheet4U.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
FEATURES · 0...-1 to 0...50 bar, 0...-15 to 0...750 psi gage1 or absolute · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use MEDIA COMPATIBILITY
Wetted materials: PPS, ceramic Al2O3 and NBR8 Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS10,11
Maximum ratings
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
Supply voltage (reverse polarity protection) KTx3...0 13...32 V KTx3...6 9...32 V KTx3...1, ...7 8...32 V KTx3...42 7...32 V Maximum load current Source/Sink Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure3
+Vs 1 Vout 3 -Vs 2
13 (8, 9)...32 V
Sensor
V
GND Internal connection (do not connect)
1 mA
-40...100°C -25...85°C 0...70°C 0 - 95 %RH 10 gRMS 50 g 2 x rated pressure
4... 20 mA output
Sensor
+Vs 1 N/C 3 -Vs 2
7...32 V
V
RL GND
Internal connection (do not connect)
December 2008 / 626
1/6
www.sensortechnics.com
www.DataSheet4U.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
(VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure KTE3001... KTE3N01G... KTE3P01G... KTE3002... KTE3005... KTE3010... KTE3016... KTE3020... KTE3025... KTE3035... KTE3050... KTU3015... KTU3N15G... KTU3P15G... KTU3030... KTU3050... KTU3100... KTU3200... KTU3300... KTU3500... KTU3750... Offset Span Offset Span
Min.
0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0
Typ.
Max.
1 1 0 2 5 10 16 20 25 35 50 15 15 0 30 50 100 200 300 500 750 0.05 0.05
Unit
bar
p si
Thermal effects (0...70°C)4 Thermal effects (-25...0°C, 70...85°C) Long term stability
6
0.02 0.02 0.03 0.03 ±0.1 ±0.3 ±0.04 1 0.005
%FSO/°C
Non-linearity, hysteresis (BSL) and repeatability5 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection
±0.3 %FSO 5 ms %FSO/V
Specification notes:
IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the B est S traight L ine fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arit.