Description 10W DC-DC Regulated Single Output Converter
Datasheet SKE10 DatasheetSKE10 Datasheet (PDF)

10W DC-DC Regulated Single Output Converter Features : SKE10 series 2:1 wide input range 4:1 wide input range(option) 1000VDC I/O isolation 3000VDC I/O isolation(option) Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Approvals: FCC / CE 2 years warranty SPECIFICATION ORDER NO. DC VOLTAGE CURRENT RANGE SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10.

  SKE10   SKE10


Document
10W DC-DC Regulated Single Output Converter Features : SKE10 series 2:1 wide input range 4:1 wide input range(option) 1000VDC I/O isolation 3000VDC I/O isolation(option) Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Approvals: FCC / CE 2 years warranty SPECIFICATION ORDER NO. DC VOLTAGE CURRENT RANGE SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C- SKE10A- SKE10B- SKE10C05 05 05 12 12 15 15 15 24 24 24 12 5V 200 ~ 2000mA 12V 84 ~ 840mA 60mVp-p 15V 66.6 ~ 666mA 60mVp-p 24V 42 ~ 420mA 80mVp-p OUTPUT RATED POWER 10W RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION Note.3 0.3% LOAD REGULATION VOLTAGE ACCURACY SWITCHING FREQUENCY VOLTAGE RANGE EFFICIENCY (Typ.) Note.4 0.5% 2.0% 200KHz min. A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC 78% 80% 81% 79% 79% Full load No load Pi network Fuse recommended 160% ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +71 (Refer to output load derating curve) A: 1100mA B: 530mA A: 28mA B: 16mA C: 270mA C: 8mA 81% 80% 82% 82% 81% 82% 83% INPUT DC CURRENT FILTER PROTECTION OVER CURRENT PROTECTION (Note. 5) SHORT CIRCUIT WORKING TEMP. 20% ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -25 ~ +105 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) TEMP. COEFFICIENT 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes VIBRATION WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMC www.DataSheet4U.com EMS IMMUNITY MTBF OTHERS DIMENSION WEIGHT I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 Class B, FCC part 15 Class B Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A 500Khrs min. MIL-HDBK-217F(25 ) 50.8*25.4*11.2mm or 2"*1"*0.44" inch (L*W*H) 32g Mechanical Specification Unit:mm 50.8 15.3 20.3 3 4 5 15.2 2.5 Pin Configuration Pin no. 1 2 3 4 5 5.8 -25 Derating Curve 11.27 Output Single + Vi n - Vi n + Vo u t No Pin - Vo u t 100 10.2 5.1 10.1 LOAD (%) 25.4 1 2 1.0 + 0.2/-0.1 2.5 BOTTOM VIEW 10.2 10.2 80 0 25 50 60 71 100 Ta ( NOTE 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. ) File Name:SKE10-SPEC 2008-05-20 .


STK4024V SKE10 SKE15


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)