FEATURES
• • • • • • • Input Spans as low as 0.4mV/V (at 10V excitation) O...
Description
JH4051I
PLUG-N-PLAY STRAIN GAUGE TRANSMITTER
FEATURES
Input Spans as low as 0.4mV/V (at 10V excitation) Offset and Nonstandard Ranges Available Excitation Adjustable from 4 to 12V Input/Output Isolation is Standard Quick-Check Red/Green Output LEDs Industry Standard Pinouts (11-Pin Socket) AC or DC Power Options
DESCRIPTION
Model JH4051I supplies DC excitation to a strain gauge or other resistance bridge, amplifies the bridge output and provides a proportional DC voltage or current. A fixed-range device, it is precisely calibrated to your specified range at the factory. Fully adjustable excitation permits use with bridge resistances as low as 120 ohms while staying within the transmitter’s 40mA excitation supply capability. A low-drift input amplifier maintains accuracy under varying ambient conditions. Input/output isolation is standard. Available options include AC or DC power choices and reverse-action Option RT (decreasing output with increasing input). Bridge applications other than strain gauges are possible: contact the factory with your requirements.
HOW TO ORDER
Model Number: JH4051I Power: Add suffix –AC (JH4051I-AC) for AC power or –DC for DC power. Specify 115Vac, 230Vac, 12Vdc or 24Vdc. Input Range: Specify range required in millivolts (mV), volts (V) or millivolts per volt (mV/V). For example, with 10V bridge excitation a range of 0/20mV is the same as 0/2 mV/V. See Specifications (on
www.DataSheet4U.com
back) for input capabilities. Offset inp...