Two-Way Power Divider
Two-Way Power Divider 1000 - 2000 MHz
Features
q q q
DS-332
V2.00
TO-8-2
2° Phase Balance Typical 20 dB Typical Midba...
Description
Two-Way Power Divider 1000 - 2000 MHz
Features
q q q
DS-332
V2.00
TO-8-2
2° Phase Balance Typical 20 dB Typical Midband Isolation 1.25:1 Typical Midband VSWR, Input
(From -55°C to +85°C) 1000 - 2000 MHz 0.5 dB Max 10 dB Min 0.2 dB Max 6° Max 1.7:1 Max 1.4:1 Max
Guaranteed Specifications*
Frequency Range Insertion Loss (Less coupling) Isolation Amplitude Balance Phase Balance VSWR (All Ports) Input Output
Operating Characteristics
Impedance Maximum Power Rating or Input Power Internal Load Dissipation Environmental MIL-STD-202 screening available. Pin Configuration ͚;P5 Output C; P9, Output D; P1 Pins P2, P4, P6 & P8 are ground. 50 Ohms Nominal 1 Watt Max 0.1 Watt Max
*All specifications apply with 50 ohm source and load impedance.
Ordering Information
Part No. DS-332 Package TO-8-2
www.DataSheet4U.com
M/A-COM Division of AMP Incorporated s North America: Tel. (800) 366-2266, Fax (800) 618-8883 s Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087 s Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks. Specifications subject to change without notice.
6-38
Two-Way Power Divider
DS-332
V2.00
Typical Performance
INSERTION LOSS
ISOLATION
VSWR
www.DataSheet4U.com
M/A-COM Division of AMP Incorporated s North America: Tel. (800) 366-2266, Fax (800) 618-8883 s Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087 s Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Conn...