Filter specification
file: tfs111b.doc 26.02.2002
version 2.0
VI TELEFILTER
Measurement condition Ambient temperature: 23°C Input power lev...
Description
file: tfs111b.doc 26.02.2002
version 2.0
VI TELEFILTER
Measurement condition Ambient temperature: 23°C Input power level: 0dBm Terminating impedances *) for input: 3,2 kΩ ||- 5,6pF for output: 3,1 kΩ || -6.2pF Characteristics
Filter specification
TFS 111B
1/5
Remark: The reference level for the relative attenuation arel of TFS 111B is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20,0 dB filter attenuation level relative to the insertion loss ae.
Data
Insertion loss (reference level) Centre frequency
ae = amin
typ. value
7 dB
tolerance / limit
11 dB
fc (30 dB-BW)
111 1 22 33 45
MHz dB dB dB dB max. min. min. min.
± 60 2 20 30 40
kHz dB dB dB dB
Relative attenuation arel fc - 500 kHz ... fc + 500 fc ± fc ± fc ± **) Group delay Ripple fc ± 500 kHz Temperature coefficient
GD
kHz MHz MHz MHz
1 2 3
MHz ... fc ± 2 MHz ... fc ± 3 MHz ... fc ± 10
300
TC 2nd order **)
ns
max 500 -
ns
- 0,032 ppm/K² 25 °C
Frequency inversion temperature To Operating temperature range Storage temperature range Input power level
- 10 °C ... + 60 °C - 40 °C ... + 85 °C max. + 10 dBm
www.DataSheet4U.com
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application not...
Similar Datasheet