Document
Embedded Power for Business-Critical Continuity
AD50 Series
50 Watts
Total Power: Input Voltage: # of Outputs: 50 Watts 90 - 264 VAC Single
Rev. 09.19.08_107 AD50 Series of 2
Electrical Specifications
Input
Special Features
• Universal AC input • Fully regulated output • EN61000-3-2 compliant • Input power <74 watts • Overcurrent and overvoltage protection • High efficiency • High MTBF • IEC320 AC input receptacle 3 pin (type C6) - AD5012N3L www.DataSheet4U.com 2 pin (type C8) - AD5012N2L • Built in EMI filter • (CISPR 22 Class B) • AC input fuse • Complies with One Watt Input Energy Star / Blue Angel Requirement • CE Mark EMC & LVD
Input range: Frequency: Inrush current: Input current: Efficiency: EMI/RFI: Safety ground leakage current:
90-264 Vac (wide range) 47-63 Hz 60A maximum @ 230VAC, cold start 25C° 2 A maximum 80% typical FCC Part 15, Class B & EN55022 (CISPR 22) Class B 300µA maximum@ 50/60 Hz, 264 VAC input - AD5012N3L 100µA maximum@ 50/60 Hz, 264 VAC input - AD5012N2L
Output
50 W Maximum Power (Po): 17 ms. minimum at full load @ 100 Vac, 47 Hz Hold-up time: Overvoltage protection: 16 - 20 V Latching type, recycle AC to reset. Overcurrent protection: Output short circuit protection auto recover Overload protection @ 110 - 120% above maximum rating DC cable length 2.5 mm center plug Cable/connector : DC plug center +v DC plug outer -v
Environmental Specifications
Operating temperature: Storage temperature: Electromagnetic susceptibility: Humidity: MTBF demonstrated: 5° to +40°C ambient -40°C to +70°C Designed to meet EN61000-4-2, -4, -5, level 4; EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3 and EN61000-3-2 Class A Operating; non-condensing 10% to 90% RH >300,000 hours at full load and 25°C ambient conditions
Safety
CSAUL UL 60950-1 CSA CSA-C22.2 no.60950-1 VDE EN/IEC60950-1 CE Mark LVD and EMC
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number
AD5012N3L AD5012N2L
Americas
Output Voltage 12 Vdc 12 Vdc Maximum Load 4.16 A 4.16 A Peak Load1 6A 6A Regulation2 ±5% ±5% Ripple P/P (PARD)3 <500 mV <500 mV
Maximum Power 50 W 50 W
Mechanical Drawing
1.61˝ (41)
1.61˝ (41)
1. Peak current lasting 200ms every 3 seconds. 2. At 25ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20MHz bandwidth and 10µF (tantalum capacitor) in parallel with a 0.1µF capacitor at rated line voltage and load ranges.
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Rev. 09.19.08_107 AD50 Series of 2
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong 0.4˝ Telephone: +852 2176 3333 (10.5) Facsimile: +852 2176 3888
4.72˝ (120) 48˝ (1219 ±20) www.powerconversion.com
For global contact, visit:
0.4˝ (10.5)
techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
4.72˝ (120)
48˝ (1219 ±20)
www.DataSheet4U.com
C8
C6
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing
Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ± 0.02” (±0.5mm) 3. Warranty: 2 year 4. Weight: 0.61 lb./ 0.28 kg 5. AC input power cord sold separately 6. Specifications at factory settings at 115VAC input, 25°C unless otherwise stated 7. AC Input Connector: IEC320, C6 or C8, mate with C5 and C7 respectively.
2.56˝ (65) 2.56˝ (65)
Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
.