DC-DC / Industry Standard Isolated Half Brick
Embedded Power for Business-Critical Continuity
AEH25 Series
300 Watts
Total Power: Input Voltage: # of Outputs: ...
Description
Embedded Power for Business-Critical Continuity
AEH25 Series
300 Watts
Total Power: Input Voltage: # of Outputs: 300 Watts (12 V @ 25 A) 48 V Single
Rev. 3.4.09_179 AEH25 Series of 2
Special Features
Electrical Specifications
Input
Input range: Input surge: Efficiency: 6-75 Vdc 3 100 V / 100 ms 93% @ 12 V (typical) < 2% 120 mV (typical) Up to 10% Vout 180 mV typical output deviation 25% step change 300 µs recovery time 115% nominal output 116% lo nominal 1500 Vdc TTL compatible (positive or negative enable logic control options)
Industry Standard Half Brick baseplate design Low output ripple and noise High capacitive load limit on start-up Regulation to zero load Fixed requency switching Industry standard features: Input UVLO, OCP, OVP, OTP; Output Adjust, Differential Remote Sense, On/Off Enable Meets Basic Insulation EU directive 2002/95/EC compliant for RoHS
Output
Regulation: (Line, Load, Temp) Ripple and noise1: Remote sense: Transient response: Overvoltage protection: Overcurrent protection: Isolation voltage:
Output voltage adjust range: ± 10% of nominal output
Control
Enable:
Environmental Specifications
Safety
UL, cUL 60950-1 Recognized TUV EN60950-1 Licensed Operating temperature: Storage temperature: Overtemperature protection: MTBF: -40 °C to +100 °C baseplate -55 °C to +125 °C 110 °C typical > 1 mission hours
Embedded Power for Business-Critical Continuity
Ordering Information
Input Voltage 36 V...