DC-DC / Intermediate Bus Converter
Embedded Power for Business-Critical Continuity
AED/ALD17
150 Watts
Total Power: 150 Watts Input Voltage: 48V # of Outp...
Description
Embedded Power for Business-Critical Continuity
AED/ALD17
150 Watts
Total Power: 150 Watts Input Voltage: 48V # of Outputs: Single
Rev. 04.02.08 AED/ALD17 1 of 2
RoHS
Electrical Specifications
Input
Input range Efficiency Over Voltage Protection Input UVLO 36V to 55V 96%@ 9.6V (typical) 60V typical 36 to 37.5V 17A max -25% / +15% Vo, nom 5% Vo (typical) 90mV (typical) Auto-restart 165kHz TTL compatible (positive or negative enable logic) 2000Vdc max
Special Features
High efficiency (96% Typical) Industry standard package 16th Brick 0.90” x 1.30" High capacitive load limit on start-up Output Enable Pin Undervoltage lockout Over Temperature Protection Meets Basic Insulation EU directive 2002/95/EC compliant for RoHS
Output
Output current Line regulation Load regulation Noise/ripple1 Over current limit Switching frequency
Over temperature protection 115°C average PCB temperature (autorecovery)
Control
Enable Isolation Voltage Input to Output
Environmental Specifications
Operating ambient temperature range Storage temperature MTBF
-40°C to +85°C ambient -55°C to +125°C >1 million hours
Safety
UL, cUL 60950 TUV EN60950
Embedded Power for Business-Critical Continuity
Ordering Information
Input Voltage 38 - 55V Options: (X) : Output Voltage 9.6V = = = = = = Output Current 17A Efficiency2 96% Typ Model Number A(X)D17Q50(N)-(6)(L)
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Rev. 04.02.08 AE...