DatasheetsPDF.com

BXA40-48T05-15-M1J Dataheets PDF



Part Number BXA40-48T05-15-M1J
Manufacturers Emerson
Logo Emerson
Description DC-DC / Low Power Isolated Industrial
Datasheet BXA40-48T05-15-M1J DatasheetBXA40-48T05-15-M1J Datasheet (PDF)

Embedded Power for Business-Critical Continuity BXA40 Series Single output Total Power: 40W Input Voltage: 18 - 36VDC 36 - 75VDC # of Outputs: Single Rev.03.08.07 bxa40s 1 of 4 Special Features • Pin-compatible with NFC40 Series • Meets telecom power supply interface standard ETS300-132-2 • EN60950, CSA C22.2 No. 950 and UL1950 safety approvals • EN61000-4-2, -3, -4, -5, -6 immunity compliant • Fixed frequency operation at 350 kHz typ. • MTBF in excess of 500,000 hours • Basic insulation syst.

  BXA40-48T05-15-M1J   BXA40-48T05-15-M1J


Document
Embedded Power for Business-Critical Continuity BXA40 Series Single output Total Power: 40W Input Voltage: 18 - 36VDC 36 - 75VDC # of Outputs: Single Rev.03.08.07 bxa40s 1 of 4 Special Features • Pin-compatible with NFC40 Series • Meets telecom power supply interface standard ETS300-132-2 • EN60950, CSA C22.2 No. 950 and UL1950 safety approvals • EN61000-4-2, -3, -4, -5, -6 immunity compliant • Fixed frequency operation at 350 kHz typ. • MTBF in excess of 500,000 hours • Basic insulation system with 1500 Vdc isolation • Remote sense on low voltage logic outputs • Output voltage trim • Available RoHS compliant • 2 year warranty The BXA40 Series providing up to 40 Watts, has been conceived as an applications specific range of dc-dc converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers two wide input voltage ranges, 18 Vdc to 36 Vdc and 36 Vdc to 75 Vdc, and is available with single outputs from 2.9 V to 12 V. The BXA40 series is designed to meet ETSI telecoms interface standards ETS300-132-2. Together with internal filtering, safety approval to IEC950 and basic insulation, the 48 V models are ideal for telecommunications applications. The 24 V models are particularly suited to industrial and test equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliance. Other features include low output ripple, overvoltage protection, indefinite short circuit protection, remote enable and remote sense. Safety VDE0805/EN60950/IEC950 File No. 14501-3336-7009 Licence No. 6296 UL1950 File No. E174104 CSA C22.2 No. 950 File No. LR41062C Embedded Power for Business-Critical Continuity Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated. Rev.03.08.07 bxa40s 2 of 4 OUTPUT SPECIFICATIONS Voltage adjustability Line regulation Load regulation Ripple and noise (20 MHz bandwidth) Low line to high line Full load to no load 2.9 V and 3.3 V 5V 12 V All models ±10% ±0.3% ±1.0% 30 mV pk-pk 50 mV pk-pk 100 mV pk-pk 20 mV rms ±0.02%/°C (See Note 9) (See Note 10) 25% to 100% load (See Note 11) 135% Vout Continuous 4.0% EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity GENERAL SPECIFICATIONS Efficiency Isolation voltage Switching frequency ±1.0% ≤5 V, ±2.0% ≥12 V Compensated line drops up to 0.5 V on 5 V models Compensated line drop up to 300 mV on 2.9 V and 3.3 V models Approvals and standards Case material Material flammability Weight 24 Vin nominal 48 Vin nominal 18-36 Vdc 36-75 Vdc (See Note 5) 48 V 5 V/ms ETS300-132 30 ms typ. CMOS/TTL Open-circuit <1 Vdc Thermal impedance (See Note 6) MTBF Size ENVIRONMENTAL SPECIFICATIONS Thermal performance Baseplate operating temperature Non-operating -40 °C to +105 °C -55 °C to +105 °C 8.5 °C/W 7.2 °C/W MIL-HDBK-217F Input/output Input/case Fixed See table 1500 Vdc 1500 Vdc 350 kHz typ. EN60950, UL1950 CSA C22.2 No. 950 Aluminum substrate with plastic case UL94V-0 85 g (3.0 oz) 500,000 hours 2.2 x 2.2 x 0.5 inches 55.9 x 55.9 x 12.7 mm EN55022, FCC part 15, (See Notes 4 and 13) EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Level B Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Temperature coefficient Overvoltage protection Short circuit protection Transient response Voltage accuracy Remote sense (See Note 8) INPUT SPECIFICATIONS Input voltage range Reverse voltage protection Max. input rise and fall time Start-up time Remote ON/OFF Logic compatibility ON OFF No air flow, no heatsink No air flow, with heatsink Embedded Power for Business-Critical Continuity Specifications Contd. Rev.03.08.07 bxa40s 3 of 4 INPUT VOLTAGE 18-36 Vdc 18-36 Vdc 36-75 Vdc 36-75 Vdc 36-75 Vdc OUTPUT VOLTAGE 3.3 V 5V 2.9 V 5V 12 V OUTPUT CURRENT (MAX.) 7A 8A 6.9 A 8.0 A 3.3 A INPUT CURRENT (1) 70 mA 40 mA 40 mA 30 mA 30 mA TYPICAL EFFICIENCY 75% 81% 77% 82% 87% REGULATION LINE (2) LOAD (3) 0.3% 0.3% 0.3% 0.3% 0.3% 1.0% 1.0% 1.0% 1.0% 1.0% MODEL NUMBER (12,14,15) BXA40-24S3V3-SMJ (8) BXA40-24S05-MJ (8) BXA40-48S2V9-SMJ (8) BXA40-48S05-MJ (8) BXA40-48S12-MJ Notes 1 2 3 4 5 6 Nominal line, at no load. Low line to high line at full load. Full load to no-load at nominal line. For conducted noise operation of the BXA40 to VDE0871, VDE0878 and EN55022 level B, see BXA40 Design Note 101. Reverse voltage protection can be implemented by putting a slow blow fuse on the positive input rail. Rate the fuse at 200 Vdc,1.5 A for 48 Vdc inputs and 100 V, 4.5 A for 24 Vdc input units. The maximum operating ambient temperature, without derating depends on internal power dissipation and hence efficiency and cooling method. Download BXA40 Design Note 101 which provides detailed t.


BXA40-48S2V9-MJ BXA40-48T05-15-M1J BXB100-24S12FLTJ


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)