DatasheetsPDF.com

Medical Adapter. DA12-050EU-M Datasheet

DatasheetsPDF.com

Medical Adapter. DA12-050EU-M Datasheet






DA12-050EU-M Adapter. Datasheet pdf. Equivalent




DA12-050EU-M Adapter. Datasheet pdf. Equivalent





Part

DA12-050EU-M

Description

AC-DC / External Wall-Mount Medical Adapter



Feature


Embedded Power for Business-Critical Con tinuity DA12-M Series 12 Watts Total P ower: Input Voltage: # of Outputs: 1 2 Watts 90 - 264 Vac Single Rev. 7.8.0 9_105 DA12-M Series  of 4 Special Fea tures • 5 V and 12 V versions • Med ical and ITE Safeties • Switching wal lmount power supply • Available in mu ltiple ac plug configurations • CE Ma rk EMC & LVD • Universal AC .
Manufacture

Emerson

Datasheet
Download DA12-050EU-M Datasheet


Emerson DA12-050EU-M

DA12-050EU-M; input • Fully regulated output • Ove rload and short circu­it protection Thermal protection • Energy Star 2. 0 and CeC approvals • Efficiency le vel V • Constant voltage • High MTB F • Built in EMI filter (CISPR 22 Cla ss B) Electrical Specifications Input Input ra­nge: Frequency: Inrush curren t: Input current: EMI/RFI: Safety groun d leakage current: 90 - 264 Vac (wid.


Emerson DA12-050EU-M

e range) 47 - 63 Hz 28 A @ 264 Vac 0.25 A rms @ 120 Vac; 0.15 A @ 240 Vac FCC P art 15, Subpart B Class B & EN55022 (CI SPR 22) Class B 100 µA @ 50/60 Hz, 264 Vac input Output Voltage (Vo): Voltag e regulation: Maximum Power (Po): Hold- up time: Overvoltage protection: Overlo ad protection: Overtemperature protecti on: Output cable/connector barrel polar ity: 5.0 V and 12.0.


Emerson DA12-050EU-M

V ± 5% @ constant voltage mode 12 W fo r 12 V models, 10 W for 5 V models 10 m s. typical at full load @ 230 Vac Non-l atching type Output shortcircuit protec tion auto recover Overload protected @ 150% above maximum rating Auto recovery DC cable with 2.5 mm x5.5mm barrel plu g DC plug center +v DC plug outer -v S afety • UL 60950, 60601-1 • cU L 60950, 60601-1 •.

Part

DA12-050EU-M

Description

AC-DC / External Wall-Mount Medical Adapter



Feature


Embedded Power for Business-Critical Con tinuity DA12-M Series 12 Watts Total P ower: Input Voltage: # of Outputs: 1 2 Watts 90 - 264 Vac Single Rev. 7.8.0 9_105 DA12-M Series  of 4 Special Fea tures • 5 V and 12 V versions • Med ical and ITE Safeties • Switching wal lmount power supply • Available in mu ltiple ac plug configurations • CE Ma rk EMC & LVD • Universal AC .
Manufacture

Emerson

Datasheet
Download DA12-050EU-M Datasheet




 DA12-050EU-M
Embedded Power for
Business-Critical Continuity
DA12-M Series
12 Watts
Total Power:
Input Voltage:
# of Outputs:
12 Watts
90 - 264 Vac
Single
Rev. 7.8.09_105
DA12-M Series
 of 4
Special Features
• 5 V and 12 V versions
• Medical and ITE Safeties
• Switching wallmount
power supply
• Available in multiple ac plug
configurations
• CE Mark EMC & LVD
• Universal AC input
• Fully regulated output
• Overload and short circu­it
protection
• Thermal protection
• Energy Star 2.0 and CeC
approvals
• Efficiency level V
• Constant voltage
• High MTBF
• Built in EMI filter
(CISPR 22 Class B)
Safety
UL 60950, 60601-1
cUL 60950, 60601-1
TUV 60950-1, 60601-1
AS/NZS 60950-1, 60601-1
CB
Certificate and report
CE EMC & LVD
PSE Denan (US only)
Electrical Specifications
Input
Input ra­nge:
90 - 264 Vac (wide range)
Frequency:
47 - 63 Hz
Inrush current:
28 A @ 264 Vac
Input current:
0.25 A rms @ 120 Vac; 0.15 A @ 240 Vac
EMI/RFI:
Safety ground
leakage current:
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B
100 µA @ 50/60 Hz, 264 Vac input
Output
Voltage (Vo):
5.0 V and 12.0 V
Voltage regulation:
± 5% @ constant voltage mode
Maximum Power (Po):
12 W for 12 V models, 10 W for 5 V models
Hold-up time:
10 ms. typical at full load @ 230 Vac
Overvoltage protection: Non-latching type
Overload protection:
Overtemperature
protection:
Output cable/connector
barrel polarity:
Output shortcircuit protection auto recover
Overload protected @ 150% above maximum rating
Auto recovery
DC cable with 2.5 mm x5.5mm barrel plug
DC plug center +v
DC plug outer -v




 DA12-050EU-M
Embedded Power for
Business-Critical Continuity
Environmental Specifications
AC Plug Configuration
Operating temperature: 0 ° to +40 °C ambient
Storage temperature: -40 °C to +85 °C
Electromagnetic
susceptibility:
Humidity:
Designed to meet EN55024
Operating; non-condensing 5% to 95% RH
Vibration:
Frequency/PSD: 5 - 350 Hz 0.0001 g2/Hz
350 - 500 Hz - 6dB/Oct.
500 Hz
0.00005g2/Hz
Acceleration: 0.21 gRMS
Duration:
20 min per second
U.S. 2-prong
Europe 2-prong
United Kingdom 3-prong
Australia 2-prong
US
EU
UK
AU
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Minimum
Load
Maximum
Load
Regulation2
Ripple
P/P (PARD)3
DA12-120US-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120EU-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120UK-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-120AU-M
12 W
12.0 V
0.2 A
1.0
± 3%
200 mV
DA12-050US-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050EU-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050UK-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
DA12-050AU-M
10 W
5.0 V
0.2 A
2.0
± 3%
50 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 mHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4­. Power supplies will operate with no-load.
Mechanical Drawings
DA12-XXXUS-M
59”
(1500)
Rev. 7.8.09_105
DA12-M Series
 of 4
2.36”
(60)
(-)
CONNECTOR PIN-OUT DETAIL
(+)




 DA12-050EU-M
DA12-XXXAU-M
59”
(1500)
2.36”
(60)
(-)
CONNECTOR PIN-OUT DETAIL
DA12-XXXEU-M
59”
(1500)
(+)
2.36”
(60)
0.685”
(17,4)
(-)
CONNECTOR PIN-OUT DETAIL
(+)
Embedded Power for
Business-Critical Continuity
Rev. 7.8.09_105
DA12-M Series
 of 4






Recommended third-party DA12-050EU-M Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)