EXB100-48S3V3-RNJ

Description

DC-DC / Industry Standard Isolated Half Brick

Manufacture

Emerson

Datasheet
Download EXB100-48S3V3-RNJ Datasheet


Emerson EXB100-48S3V3-RNJ

EXB100-48S3V3-RNJ; EXB100 Series DC-DC CONVERTERS • • • • • • • Single output 1 00 W DC-DC Isolated Converters NEW Prod uct 1 Ultra wide trim range, 60% to 1 10% (1.08 Vdc to 5.5 Vdc) High efficien cy, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc Basi c insulation (input to output) Industry standard half-brick pin-out No minimum load Overvoltage and overtemperature p rotection Remote ON/OFF Available .


Emerson EXB100-48S3V3-RNJ

RoHS compliant The EXB100 series of 100 W single output isolated dc-dc convert ers are specially designed to meet the power needs of low voltage silicon. Hou sed in an open-frame package with stand ard footprint, these latest generation converters offer efficiencies as high a s 91.5% (typical on 5 V at 20 A). The s eries comprises two 48 V input models w ith 5 V and 3.3 V .


Emerson EXB100-48S3V3-RNJ

outputs. The 3.3 V model features a wide input range, trimmable output voltage and 30 A output (the 5 V model is limit ed to 20 A). Remote sense and remote ON /OFF facilities are included as standar d, and the converters are comprehensive ly protected against overcurrent, overv oltage and overtemperature conditions. 2 YEAR WARRANTY All specifications are typical at nominal.



Part

EXB100-48S3V3-RNJ

Description

DC-DC / Industry Standard Isolated Half Brick

Manufacture

Emerson

Datasheet
Download EXB100-48S3V3-RNJ Datasheet




 EXB100-48S3V3-RNJ
EXB100 Series
Single output
DC-DC CONVERTERS 100 W DC-DC Isolated Converters
Ultra wide trim range, 60% to 110% (1.08 Vdc to 5.5 Vdc)
High efficiency, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc
Basic insulation (input to output)
Industry standard half-brick pin-out
No minimum load
Overvoltage and overtemperature protection
Remote ON/OFF
Available RoHS compliant
1
NEW Product
The EXB100 series of 100 W single output isolated dc-dc converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5 V at 20 A). The series comprises two 48 V input models
with 5 V and 3.3 V outputs. The 3.3 V model features a wide input range, trimmable
output voltage and 30 A output (the 5 V model is limited to 20 A). Remote sense and
remote ON/OFF facilities are included as standard, and the converters are
comprehensively protected against overcurrent, overvoltage and overtemperature
conditions.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
60% to 110%
Output setpoint accuracy
1.5%
Line regulation
Low line to high line
±0.2% max.
Load regulation
Full load to min. load
±0.4% max.
Total error band
3.0%
Minimum load
0%
Overshoot
At turn-on and turn-off
None
Undershoot
None
Ripple and noise
5 Hz to 20 MHz
(See Note 1)
100 mV pk-pk
50 mV rms
Transient response
(See Note 2)
Deviation
150 mV
300 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range
36-75 Vdc
Input current
No load
Remote OFF
150 mA
20 mA
Input current (max.)
(See Note 3)
3.15 A max. @ Io max.
and Vin = 36-75 Vdc
Input reflected ripple
(See Note 4)
60 mA (pk-pk)
Remote ON/OFF
Logic compatibility
ON
OFF
(See Note 5)
Open collector ref to -input
>2 Vdc
<1.2 Vdc
Undervoltage lockout
Power up
Power down
36 V
30 V
Start-up time
(See Note 6)
Power up
Remote ON/OFF
40 ms
35 ms
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 (See Note 7)
EN55022 (See Note 7)
EN55022
(See Longform Datasheet)
Level A
Level B
Level A
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-3 10 V/m
EN61000-4-6 10 V
EN61000-4-6 10 V
ETS 300 132-2, ETR 283
(See Note 5)
GENERAL SPECIFICATIONS
Efficiency
See table
Basic insulation
Input/output
1500 Vdc
Switching frequency
(Fixed)
5V
3.3 V
300 kHz typ.
220 kHz typ.
Approvals and
standards (See Note 8)
TÜV Product Service
UL/cUL60950
Material flammability
UL94V-0
Weight
45 g (1.59 oz)
MTBF
Representative model:
MIL-HDBK-217F
1,034,000 hours
100% load, ground benign
BELLCORE 332
591,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Altitude derating
(above sea level)
Operating ambient
temperature
Non-operating
3,000 m
10,000 m
-40 °C to +90 °C
-40 °C to +125 °C
20%
50%
File Name: exb100s.pdf Rev: 18 Apr 2006





 EXB100-48S3V3-RNJ
EXB100 Series
Single output
DC-DC CONVERTERS 100 W DC-DC Isolated Converters
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
2
NEW Product
OUTPUT
POWER
(MAX.)
100 W
100 W
INPUT
VOLTAGE
36-75 Vdc
36-75 Vdc
OVP
6.0 Vdc
3.9 Vdc
OUTPUT
VOLTAGE
5V
3.3 V
OUTPUT
CURRENT
(MIN.)
0A
0A
OUTPUT
CURRENT
(MAX.)
20 A
30 A
EFFICIENCY
(TYP.)
91.5%
90.5%
REGULATION
LINE LOAD
MODEL
NUMBER (10)
±0.2%
±0.2%
±0.4% EXB100-48S05J (9)
±0.4% EXB100-48S3V3-RJ
Notes
1 Measured as per recommended set-up. See Application Note 129 for details.
2 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 Recommended input fusing is a 5 A HRC 200 V rated fuse.
4 Measured with external filter. See Application Note 129 for details.
5 Signal line assumed <3 m in length.
6 Start-up into resistive load.
7 The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
8 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9 Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S05-RJ.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
PROTECTION
Short circuit
Overvoltage
TELECOM SPECIFICATION
Central office interface A
Continuous
Non-latching clamp
ETS300-132-2 input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PIN CONNECTIONS
PIN NUMBER
FUNCTION
1 -Vin
2 No Pin
3 Remote ON/OFF
4 +Vin
5 +Vout
6 +Sense
7 Trim
8 -Sense
9 -Vout
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 02 02 38572 031
Max open-frame
converter height
seating plane
Ø0.040 ±0.002
(Ø1.02 ±0.05)
6 Places Ø0.080 ±0.002
Minimum clearance from
seating plane to
(Ø2.03 ±0.05)
2 Places
underside components
All dimensions in inches (mm)
General tolerance ±0.01in (±0.25mm)
except where specified otherwise
2.280±0.02
(57.91±0.5)
Vin-
Remote
ON/OFF
Vin+
1.900
(48.26)
Vo-
Sense-
Trim
Sense+
Vo+
Bottom View
Datasheet © Artesyn Technologies® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:  Application Note  Longform Datasheet
www.artesyn.com
File Name: exb100s.pdf Rev: 18 Apr 2006








Recommended third-party EXB100-48S3V3-RNJ Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)