DatasheetsPDF.com

Bus Converter. IBC32AEN4896-REJ Datasheet

DatasheetsPDF.com

Bus Converter. IBC32AEN4896-REJ Datasheet






IBC32AEN4896-REJ Converter. Datasheet pdf. Equivalent




IBC32AEN4896-REJ Converter. Datasheet pdf. Equivalent





Part

IBC32AEN4896-REJ

Description

DC-DC / Intermediate Bus Converter



Feature


Embedded Power for Business-Critical Con tinuity IBC32 Eighth-Brick Series Fixe d Ratio 2nd Generation IBC Total Power: 300W Input Voltage: 38 - 55 Vdc Rev.0 5.12.08 eighth_brick_300w_ibc32 1 of 4 Electrical Specifications Output Spec ial Features • 48 V input with isolat ed 9.6 V output • Ultra-high efficien cy, 97% • Unprecedented usable output power levels • High pow.
Manufacture

Emerson

Datasheet
Download IBC32AEN4896-REJ Datasheet


Emerson IBC32AEN4896-REJ

IBC32AEN4896-REJ; er density open-frame technology • Wid e operating ambient temperature range Industry standard eighthbrick footpr int and pinout • Low profile, 0.48" ( 12.2 mm) • Meets basic insulation req uirements of EN60950-1 • Remote ON/OF F and overtemperature protection • Ro HS compliant • 2 year warranty Line regulation: Low line to high line Load regulation Full load to min. loa.


Emerson IBC32AEN4896-REJ

d Total error band (including setVin = 3 8 V to 55 V point, line, load and tempe rature) Minimum load Overshoot Undersho ot Ripple and noise 5 - 20 MHz At turn on and turn-off (See note 2) See table See table 7.0 - 11.0 Vdc 0A None None 100 mV pk-pk typ. 30 mV rms typ. Input Input voltage range Input current Inpu t current (max.) Input reflected ripple (See note 4) Remo.


Emerson IBC32AEN4896-REJ

te ON/Off Logic compatiblity On OFF Unde rvoltage lockout 38 - 55 Vdc Remote OFF (See note 1) 550 mA (pk-pk) 200 MA rms (see note 6) Open collector ref. to- i nput >2.4 Vdc <0.8 Vdc 35 V 33.5 V 12 m s 1 ms 7 mA typ. 8.6 A max. @ lo max. a nd Vin = min. rated Safety UL/cUL 6095 0-1, 1st Edition EN 60950-1 VDE Startu p time (see note 3) Power-up Power-dow n Power-up Remote .

Part

IBC32AEN4896-REJ

Description

DC-DC / Intermediate Bus Converter



Feature


Embedded Power for Business-Critical Con tinuity IBC32 Eighth-Brick Series Fixe d Ratio 2nd Generation IBC Total Power: 300W Input Voltage: 38 - 55 Vdc Rev.0 5.12.08 eighth_brick_300w_ibc32 1 of 4 Electrical Specifications Output Spec ial Features • 48 V input with isolat ed 9.6 V output • Ultra-high efficien cy, 97% • Unprecedented usable output power levels • High pow.
Manufacture

Emerson

Datasheet
Download IBC32AEN4896-REJ Datasheet




 IBC32AEN4896-REJ
Embedded Power for
Business-Critical Continuity
IBC32
Eighth-Brick
Series
Fixed Ratio
2nd Generation IBC
Total Power: 300W
Input Voltage: 38 - 55 Vdc
Rev.05.12.08
eighth_brick_300w_ibc32
1 of 4
Special Features
• 48 V input with isolated 9.6 V
output
• Ultra-high efficiency, 97%
• Unprecedented usable
output power levels
• High power density
open-frame technology
• Wide operating ambient
temperature range
• Industry standard eighth-
brick footprint and pinout
• Low profile, 0.48" (12.2 mm)
• Meets basic insulation
requirements of EN60950-1
• Remote ON/OFF and
overtemperature protection
• RoHS compliant
• 2 year warranty
Safety
UL/cUL 60950-1, 1st Edition
EN 60950-1 VDE
Electrical Specifications
Output
Line regulation:
Low line to high line
Load regulation
Full load to min. load
Total error band (including set- Vin = 38 V to 55 V
point, line, load and temperature)
See table
See table
7.0 - 11.0 Vdc
Minimum load
Overshoot
Undershoot
Ripple and noise
5 - 20 MHz
At turn on and turn-off
(See note 2)
0A
None
None
100 mV pk-pk typ.
30 mV rms typ.
Input
Input voltage range
Input current
Input current (max.)
Input reflected ripple
(See note 4)
38 - 55 Vdc
Remote OFF
(See note 1)
550 mA (pk-pk)
200 MA rms
7 mA typ.
8.6 A max. @ lo max.
and Vin = min. rated
Remote ON/Off
Logic compatiblity
On
OFF
Undervoltage lockout
Startup time (see note 3)
Power-up
Power-down
Power-up
Remote ON/OFF
(see note 6)
Open collector ref. to- input
>2.4 Vdc
<0.8 Vdc
35 V
33.5 V
12 ms
1 ms




 IBC32AEN4896-REJ
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics
Immunity:
ESD air enclosure
Input transients:
EN61000-4-2 8 kV, 6 kV
(Air contact)
Input voltage
>58 V
>60 V
>62 V
Duration before shutdown
2 seconds
1 second
0 seconds
General Specifications
Efficiency
Basic insulation
Input/output
Switching frequency Fixed
Approvals and
standards (see note 5)
97%
2250 Vdc
350 kHz typ.
EN60950-1 VDE
UL/cUL60950-1
Material flammability
Weight
MTBF
Representative model:
Telcordia Tech SR-332
48 Vin, 40 °C, 50% load
ground benign
UL94V-0
37 g (1.31 oz)
2,100,000 hours
Rev.05.12.08
eighth_brick_300w_ibc32
2 of 4
Environmental Specifications
Thermal
Operating ambient, -40 °C to +85 °C
performance temperature
Non-operating
-55 °C to +125 °C
Protection
Short-circuit Hiccup
Overvoltage (See note 9)
Thermal
Non-latching
125 °C hot spot
Ordering Information
Output
Power
(Max.)
Input
Voltage
300 W
38 - 55 Vdc
Output
Voltage
9.6 V
Output
Current
(Min.)
0A
Output Current Efficiency
(Max.)
(Typ.)
32 A 97%
Set Point
Accuracy %
---
Regulation2
Line %
ΔVin/5
Load
2.3%
Model Number
IBC32AEN4896J
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Part Number System with Options
Product Family
IBC
Rated Output
Current
32A
Form Factor
E
IBC Intermediate 32 A = 32
Bus Converter Amps at 48 V
2nd Generation
E = Eighth-
Brick
Input Voltage Type
N
Input
Voltage
48
Output
Voltage
96 -
Remote
ON/OFF Logic
R
Package, Body
Height
E
Pin Length
Options
N
RoHS
Compliance (10)
J
T = Narrow Input
Fixed Ratio
S = Narrow Input
Semi-reguated
N = Narrow Telecom
Fixed Ratio
W = Wide Telecom
Semi-reguated
48 = 48 V 96 = 9.6 V
Blank =
Positive
R = Negative
(See Note 6)
E = Open-
frame, 0.48 in
(12.2 mm)
Blank = 0.188 ”
(4.78 mm)
N = 0.145 ”
(3.68 mm)
K = 0.110 ”
(2.79 mm)
J = Pb-free
(RoHS 6/6
compliant)
Notes
1 Recommended input fusing is a 20 A HRC 250 V rated fuse.
2 Measured with external filter. See Application Note 208 for details.
3 Start-up into resistive load.
4 Peak to peak measured without external Pi filter. Significant reduction
possible with external filter. See Application Note 208 for details.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Active-low remote ON/OFF option is also available. Please add the suffix ‘-R’
to the part number, e.g. IBC32AEN4896-REJ.
7 Maximum output power at maximum input voltage.
8 Efficiency at 100% maximum output voltage.
9 After an input overvoltage latch off, the input voltage must be returned to 55
V or lower for unit to restart.
10 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.




 IBC32AEN4896-REJ
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.1450.020
[3.680.51]
0.90
[22.9]
0.300
[7.62]
0.300
[7.62]
0.45
[11.4]
1
2
3
2.30
[58.4]
2.000
[50.80]
0.145 [3.68]
ø0.092 [2.34]
0.04 [1.0]
MIN
0.060 [1.52]
0.040 [1.02]
Solder venting
feature
5
4
0.48 [12.2]
MAX
ø0.093 [2.36]
ø0.062 [1.57]
ø0.122 [3.10]
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
x.xx 0.02 (x.x 0.5)
x.xxx 0.010 (x.xx 0.25)
Pin connections
Pin Number
1
2
3
4
5
Function
+Vin
Remote ON/OFF
-Vin
-Vout
+Vout
Rev.05.12.08
Americas
eighth_brick_300w_ibc32
5810 Van Allen Way
3 of 4
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.






Recommended third-party IBC32AEN4896-REJ Datasheet