Document
Embedded Power for Business-Critical Continuity
LPS100-M Series
150 Watts
Total Power: Input Voltage: # of Outputs: 80 - 150 Watts 90 - 264 Vac Single
Rev. 4.30.09_29 LPS100-M Series of 3
Special Features
• • • • • • • • • • • • • • Medical and ITE safeties Active power factor correction 2” x 4” footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection Isolated12 V Fan output LPX50 Enclosure kit available
Electrical Specifications
Input
Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Safety ground leakage current: 90 - 264 Vac; 120 - 300 Vdc 47-63 Hz 50 A max., cold start @ 25 °C 88% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 275 µA @ 50/60 Hz, 264 Vac input
Output
100 W for convection (80 W for LPS102-M); 150 W with 30 CFM forced air (120 W for LPS102-M) Adjustment range: ± 10% minimum on the main outputs Fan output: 12 V @ 1 A isolated, ± 10% Hold-up time: 10 ms @ 150 W load, 120 Vac input Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-160% above rating Overvoltage protection: 15-35% above nominal output Maximum power:
Logical Control
Power failure: Open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Safety
• • • • • • TUV 60950, 60601-1 UL 60950, 60601-1 cULus 60950, 60601-1 TUV 60950, 60601-1 CB Certificate & report CE Mark (LVD)
Remote sense:
Embedded Power for Business-Critical Continuity
Environmental Specifications
Operating temperature: 0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up -40 °C to +85 °C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25 °C ambient conditions Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: MTBF demonstrated
Rev. 4.30.09_29 LPS100-M Series of 3
Mechanical Drawing
M1
VR1 Output Voltage Adjust Pot M2
1 4 8
SK203 SK2
GND
SK1 1 3
2.00" (50.8)
1
3.73" (94.7) 4.00" (101.6)
0.197” (5.0) Minimum Standoff Height
0.16" (4.0) 1.29" (33.0)
1.72" (43.8) Mounting Hole Ø0.16"[4.0] 4 Places Max. Screw Head Diameter .22” (5.6)
1
4
SK5
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number LPS102-M LPS103-M LPS104-M LPS105-M LPS108-M Output Voltage 5V 12 V 15 V 24 V 48 V Minimum Load 0A 0A 0A 0A 0A Maximum Load with Convection Cooling 16 A 8.3 A 6.7 A 4.2 A 2.1 A Maximum Load with 30CFM Peak Load Regulation2 Forced Air 24 A 12.5 A 10 A 6.3 A 3.1 A 30 A 14 A 11 A 7A 3.5 A ± 2%.