DatasheetsPDF.com

- 135W. LPS115 Datasheet

DatasheetsPDF.com

- 135W. LPS115 Datasheet






LPS115 135W. Datasheet pdf. Equivalent




LPS115 135W. Datasheet pdf. Equivalent





Part

LPS115

Description

AC-DC / 86W - 135W



Feature


110 Watts LPS110 Series Total Power: 8 0-110 Watts Input Voltage: 85-264 VAC 1 20-300 VDC # of Outputs: Single Electr ical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 4 7-440 Hz <18 A peak @ 115 VAC; <36 A pe ak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at ful l load FCC Class B conducted CISPR 22 C lass B conducted EN.
Manufacture

Emerson

Datasheet
Download LPS115 Datasheet


Emerson LPS115

LPS115; 55022 Class B conducted VDE 0878 PT3 Cla ss B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W wi th 30 CFM forced air ±5% minimum 20 ms @80 W load, 115 VAC nominal line Short circuit protection. Case overload prot ected @ 110-145% above peak rating 5 V output: 5.7-6.7 VDC. Other outputs 10% to 20% above nominal output. Latching t ype, recycle AC to .


Emerson LPS115

reset. TTL logic signal goes high 50-150 msec after main output. It goes low at least 4 msec before loss of regulation . Compensates for 0.5 V lead drop min. Will operate without remote sense conne cted. Reverse connection protected. In put current Efficiency EMI filter Spec ial Features • • • • • • • • • • Universal input High efficiency Remote sense Built-in EMI fil.


Emerson LPS115

ter Low output ripple Adjustable output Power fail Overvoltage protection Overl oad protection Optional L bracket (-B s uffix) Cover kit available LPX110-C Sa fety ground leakage current Output Max imum power Adjustment range Hold-up tim e Overload protection Overvoltage prot ection Environmental Operating tempera ture: 0° to 50°C ambient derate each output at 2.5% per d.

Part

LPS115

Description

AC-DC / 86W - 135W



Feature


110 Watts LPS110 Series Total Power: 8 0-110 Watts Input Voltage: 85-264 VAC 1 20-300 VDC # of Outputs: Single Electr ical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 4 7-440 Hz <18 A peak @ 115 VAC; <36 A pe ak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at ful l load FCC Class B conducted CISPR 22 C lass B conducted EN.
Manufacture

Emerson

Datasheet
Download LPS115 Datasheet




 LPS115
110 Watts
LPS110 Series
Total Power: 80-110 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Special Features
• Universal input
• High efficiency
• Remote sense
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Power fail
• Overvoltage protection
• Overload protection
• Optional L bracket (-B suffix)
• Cover kit available LPX110-C
Environmental
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Electrical Specs
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground
leakage current
Output
Maximum power
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Logic Control
Power failure
Remote sense
85-264 VAC
120-300 VDC
47-440 Hz
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
2.5 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC-input
80 W for convection;
110 W with 30 CFM forced air
±5% minimum
20 ms @80 W load, 115 VAC nominal
line
Short circuit protection. Case overload
protected @ 110-145% above peak
rating
5 V output: 5.7-6.7 VDC. Other outputs
10% to 20% above nominal output.
Latching type, recycle AC to reset.
TTL logic signal goes high 50-150 msec
after main output. It goes low at least 4
msec before loss of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE
UL
CSA
NEMKO
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1245 (LC #84997)
E132002
LR53982C
P95100376
1563, 1564, 1565, 1566, 1567
Technical Support: (888) 41-ASTEC or (407) 241-2752
100
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.10.03




 LPS115
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPS113
LPS114
LPS115
LPS118
12 V
15 V
24 V
48 V
0 A 6.7 A
0 A 5.3 A
0 A 3.3 A
0 A 1.7 A
9.2 A
7.3 A
4.6 A
2.3 A
10.4 A
8.3 A
5.2 A
2.6 A
±2%
±2%
±2%
±2%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load.
Note: -B suffix added to model number indicates L bracket option.
-B Bracket
120 mV
150 mV
240 mV
480 mV
Pin Assignments
ConnectorLPS113 LPS114 LPS115 LPS118
SK1-1
SK1-3
SK1-5
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
SK201-1
SK201-2
SK202-1
SK202-2
+12 V
+12 V
+12 V
Common
Common
Common
Common
+12 V
+12 V
+sense
-sense
Pok
GND
+15 V
+15 V
+15 V
Common
Common
Common
Common
+15 V
+15 V
+sense
-sense
Pok
GND
+24 V
+24 V
+24 V
Common
Common
Common
Common
+24 V
+24 V
+sense
-sense
Pok
GND
+48 V
+48 V
+48 V
Common
Common
Common
Common
+48 V
+48 V
+sense
-sense
Pok
GND
Mating Connectors
AC Input: Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC Outputs:
Molex 09-50-8091 (USA)
09-91-0900 (UK)
PINS: 08-58-0111
Remote sense/power fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Astec Connector Kit #70-841-007, includes all of the above
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L Bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Warranty: 1 year
8. Weight: 1.25 lb / 0.57 kg
www.astecpower.com
4.28"
(108.6)
2.5"
(63.5)
2.2"
(56)
0.86"
(21.8)
0.25"
(6.35)
4.0"
(101.6)
3.5"
(88.9)
1
3
0.25"
(6.35)
1.80"
(45.7)
0.12"
(3)
#6-32 PEM
6 places
6.4"
(162.6)
7.3"
(185.5)
5.9"
(150.0)
6.5"
(165.1)
7.0"
(177.8)
M2
SK 202
(POK)
1
2
3
SK 201
(+S) 1
(-S) 2
12
4
5
6
7
8
9
GND
N
L
SK 1
M1
0.156" (4)
DIA (4 places)
101










Recommended third-party LPS115 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)