DatasheetsPDF.com

260W Medical. LPS173-M Datasheet

DatasheetsPDF.com

260W Medical. LPS173-M Datasheet







LPS173-M Medical. Datasheet pdf. Equivalent




LPS173-M Medical. Datasheet pdf. Equivalent





Part

LPS173-M

Description

AC-DC / 136W - 260W Medical

Manufacture

Emerson

Datasheet
Download LPS173-M Datasheet


Emerson LPS173-M

LPS173-M; Embedded Power for Business-Critical Con tinuity LPS170-M Series Medical 175 Wa tts Total Power: Input Voltage: # of Outputs: 100 - 175 Watts 85-264 VA C 120-300 VDC Single Rev. 12.08.08_113 LPS170-M Series  of 3 Electrical Spe cifications Special Features • • • • • • • • • • • • • • Medical saf ety approvals Active power factor correction IEC.


Emerson LPS173-M

EN61000-3-2 compliance Wide Range Adjus table output Remote sense on main outpu t Single wire current sharing Power fai l and remote inhibit Built-in EMI filte r Low output ripple Overvoltage protect ion Overload protection Thermal overloa d protection DC power good 5 V standby output 12 V Aux output Optional cover (-C suffix) Input Input ra­nge: Frequ ency: Inrush curren.


Emerson LPS173-M

t: Efficiency: EMI filter: 85-264 VAC; 1 20-300 VDC 47-67 Hz 38 A max, cold star t @ 25 °C 75% typical at full load FCC Class B conducted CISPR 22 Class B con ducted EN55022 Class B conducted VDE 08 78 PT3 Class B conducted 0.99 typical < 250 µA @ 50/60 Hz, 264 VAC inputS Pow er Factor: Safety ground leakage curren t: Output Maximum power: 110 W convect ion (75 W with cover.



Part

LPS173-M

Description

AC-DC / 136W - 260W Medical

Manufacture

Emerson

Datasheet
Download LPS173-M Datasheet




 LPS173-M
Embedded Power for
Business-Critical Continuity
LPS170-M Series
Medical
175 Watts
Total Power:
Input Voltage:
# of Outputs:
100 - 175 Watts
85-264 VAC
120-300 VDC
Single
Rev. 12.08.08_113
LPS170-M Series
 of 3
Special Features
• Medical safety approvals
• Active power factor correction
• IEC EN61000-3-2 compliance
• Wide Range Adjustable output
Remote sense on main output
• Single wire current sharing
• Power fail and remote inhibit
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• 5 V standby output
• 12 V Aux output
• Optional cover (-C suffix)
Safety
VDE
UL
CSA
CE
0750/EN60601-1
(IEC601)
UL2601
CSA 22.2 No. 601.1
Mark (LVD)
Electrical Specifications
Input
Input ra­nge:
85-264 VAC; 120-300 VDC
Frequency:
47-67 Hz
Inrush current:
38 A max, cold start @ 25 °C
Efficiency:
EMI filter:
75% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power Factor:
0.99 typical
Safety ground
leakage current:
Output
Maximum power:
<250 µA @ 50/60 Hz, 264 VAC inputS
110 W convection (75 W with cover)
175 W with 30 CFM forced air
(130 W with cover)
Adjustment range:
2:1 wide ratio minimum
Standby outputs:
Hold-up time:
5 V @ 2 A regulated ±5%
20 ms @175 W load at nominal line
Overload protection:
Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection: 10% to 40% above nominal output
Aux output:
12 V @ 1 A -5 %, +10%





 LPS173-M
Embedded Power for
Business-Critical Continuity
Logic Control
Power failure:
Remote inhibit:
Remote sense:
DC - OK:
TTL logic signal goes high 100 - 500 msec after V1 output; It goes low
at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It goes
low when there is a loss of regulation
Environmental Specifications
Operating temperature: 0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
Low temperature start: -20 °C
Temperature coefficient: ±0.4% per °C
Storage temperature: -40° to 85 °C
Electromagnetic
susceptibility:
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four
major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load
with 30CFM
forced Air
Peak Load 1 Regulation 2
Ripple P/P
(PARD)3
LPS172-M 5 V (2.5 - 6 V) 0 A
22 A
35 A
38 A
±2%
50 mV
LPS173-M 12 V (6 - 12 V) 0 A
9.1 A
15 A
16.5 A
±2%
120 mV
LPS174-M 15 V (12 - 24 V) 0A
7.3 A
12 A
13.2 A
±2%
<1%
LPS175-M 24 V (24 - 54 V) 0A
4.5 A
7.5 A
8.2 A
±2%
<1%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load
ranges.
4. Remote inhibit resets OVP latch.
Note: -C suffix added to the model number indicates cover option.
Rev. 12.08.08_113
LPS170-M Series
 of 3
Pin Assignments
Connector LPS17x
SK1 PIN 1
+12 V
PIN 2
Pin 3
5 V Standby
Common
Pin 4
V1 SWP
PIN 5
Common
PIN 6
PIN 7
+V1 sense
Sense common
PIN 8
PIN 9
Remote inhibit
DC poer good
PIN 10
POK
SK2
TB-1
COMMON
TB-2
Main output
SK3
PIN 1
GROUND
PIN 2
LINE
Pin 5
NEUTRAL
Mating­ Connectors
AC Input (SK4):
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
DC Outputs (SK3): Molex 19141-0058
Control Signals
(SK1):
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Emerson Network Power Connector Kit #70-841-016
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 1.8 lb / 0.85 kg





 LPS173-M
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
15
6 10
SK1
+-
SK3
Voltage Adj
POT
5 31
SK4
1.50
(38.1)
0.75
(19.0)
0.95
(24.0)
0.55
(14.0)
6.61
7.4
(168.0) (188.0)
8.5
(216.0)
M3
#6-32
#6-32(8 PLACES)
M3(8 PLACES)
­Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 12.08.08_113
LPS170-M Series
 of 3
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.



Recommended third-party LPS173-M Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)