DatasheetsPDF.com

85W Medical. LPT62-M Datasheet

DatasheetsPDF.com

85W Medical. LPT62-M Datasheet






LPT62-M Medical. Datasheet pdf. Equivalent




LPT62-M Medical. Datasheet pdf. Equivalent





Part

LPT62-M

Description

AC-DC / 10W - 85W Medical



Feature


Embedded Power for Business-Critical Con tinuity LPT60-M Series 60 Watts Medica l Total Power: Input Voltage: # of Outp uts: 60 - 80 Watts 85 - 264 VAC 120 - 3 00VDC Triple Rev. 06.15.07 LPT60-M Ser ies 1 of 3 RoHS Electrical Specificat ions Special Features • • • • • • • • • • Medical safe ty approvals Universal input 3" x 5" fo otprint Remote sense on main output Buil.
Manufacture

Emerson

Datasheet
Download LPT62-M Datasheet


Emerson LPT62-M

LPT62-M; t-in EMI filter Low output ripple Adjust able 5V output Overvoltage protection O verload protection 110KHz switching fre quency LPX60 enclosure kit available I nput Input range Frequency Inrush curre nt Input current Efficiency EMI 85-264V AC 120-300VDC 47-440Hz <18A peak @ 115V AC; <36A peak @ 230VAC, cold start @ 25 °C 1.5A max. (RMS) @ 115VAC 70% typica l at full load FCC .


Emerson LPT62-M

Class A conducted; CISPR 22 Class A cond ucted EN55022 Class A conducted; VDE 08 78 PT3 Class A conducted <75μA max. @ 50/60 Hz, 264VAC input Safety ground l eakage current Output Maximum Power Cr oss regulation Adjustment range Hold-up time Overload protection 0750/EN60601- 1 (IEC601) 21310-3336-0015 UL2601 E1825 60 CSA 22.2 No. 601.1 LR109492 Mark (LV D) Overvoltage prot.


Emerson LPT62-M

ection Remote sense 60W for convection; 80W with 30CFW forced air ±2% on outpu t 1; ±5% on outputs 2, 3 -5, +10% mini mum 20ms @ 60W load, 115VAC nominal lin e Short circuit protection on all outpu ts. Case overload protected @ 110% to 1 45% above peak rating 5.7 to 6.7 VDC on the main output Compensates for 0.5 V lead drop min. Will operate without rem ote sense connected..

Part

LPT62-M

Description

AC-DC / 10W - 85W Medical



Feature


Embedded Power for Business-Critical Con tinuity LPT60-M Series 60 Watts Medica l Total Power: Input Voltage: # of Outp uts: 60 - 80 Watts 85 - 264 VAC 120 - 3 00VDC Triple Rev. 06.15.07 LPT60-M Ser ies 1 of 3 RoHS Electrical Specificat ions Special Features • • • • • • • • • • Medical safe ty approvals Universal input 3" x 5" fo otprint Remote sense on main output Buil.
Manufacture

Emerson

Datasheet
Download LPT62-M Datasheet




 LPT62-M
Embedded Power for
Business-Critical Continuity
LPT60-M Series
60 Watts
Medical
Total Power:
Input Voltage:
# of Outputs:
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Triple
RoHS
Rev. 06.15.07
LPT60-M Series
1 of 3
Special Features
• Medical safety approvals
• Universal input
• 3" x 5" footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5V output
• Overvoltage protection
• Overload protection
• 110KHz switching frequency
• LPX60 enclosure kit available
Safety
VDE 0750/EN60601-1 (IEC601)
21310-3336-0015
UL UL2601
E182560
CSA CSA 22.2 No. 601.1
LR109492
CE Mark (LVD)
Electrical Specifications
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI
Safety ground
leakage current
85-264VAC
120-300VDC
47-440Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1.5A max. (RMS) @ 115VAC
70% typical at full load
FCC Class A conducted; CISPR 22 Class A conducted
EN55022 Class A conducted;
VDE 0878 PT3 Class A conducted
<75μA max. @ 50/60 Hz, 264VAC input
Output
Maximum Power
Cross regulation
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
60W for convection; 80W with 30CFW forced air
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 60W load, 115VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.




 LPT62-M
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Vibration:
Storage temperature:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
-40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated:
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
LPT62-M
Output
Voltage
+5V
+12V
-12V
Minimum
Load
0.7A
0.3A
0A
Maximum Load
with Convnection
cooling
7A
3A
0.7A
Maximum Load
with 30CFM
Forced Air
8A
3.5A
1A
LPT63-M
+5V
+15V
-15V
0.7A
0.3A
0A
7A
2.8A
0.7A
8A
3.3A
1A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
Peak Load1
10A
6A
1.5A
10A
4A
1.5A
Regulation2
±2%
±5%
±5%
±2%
±5%
±5%
Ripple P/P (PARD)3
50mV
120mV
120mV
50mV
150mV
150mV
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
Rev. 06.15.07
LPT60-M Series
2 of 3




 LPT62-M
Mechanical Drawing
Pin Assignments
Connector
SK1-1
SK1-3
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
LPT62-M
Neutral
Line
+12V
+5V
+5V
Common
Common
-12V
+Sense
-Sense
LPT63-M
Neutral
Line
+15V
+5V
+5V
Common
Common
-15V
+Sense
-Sense
Mating Connectors
AC Input:
DC Outputs:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense: Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input,
25°C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.75lbs/0.34kg
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 06.15.07
LPT60-M Series
3 of 3
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com
www.artesyn.com
technicalsupport@astec.com
technicalsupport@artesyn.co
m
While every precaution has been taken to ensure
accuracy and completeness in this literature,
Emerson Network Power assumes no responsibility,
and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Printed in US A
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.






Recommended third-party LPT62-M Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)