DatasheetsPDF.com

- 85W. LPT65 Datasheet

DatasheetsPDF.com

- 85W. LPT65 Datasheet






LPT65 85W. Datasheet pdf. Equivalent




LPT65 85W. Datasheet pdf. Equivalent





Part

LPT65

Description

AC-DC / 10W - 85W

Manufacture

Emerson

Datasheet
Download LPT65 Datasheet


Emerson LPT65

LPT65; Embedded Power for Business-Critical Con tinuity LPT60 Series 60 Watts Total Po wer: Input Voltage: # of Outputs: 60 - 80 Watts 85 - 264 VAC 120 - 300VDC Trip le Rev. 03.24.08 LPT60 Series 1 of 3 RoHS Electrical Specifications Special Features • • • • • • • • • Universal input 3" x 5" foot print Remote sense on main output Built -in EMI filter Low output ripple Adjus.


Emerson LPT65

table main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available Input Input range: Frequency: Inrush current: Input current: Efficiency: EMI : 85-264VAC 120-300VDC 47-440Hz <18A pe ak @ 115VAC; <36A peak @ 230VAC, cold s tart @ 25°C 1.5A max. (RMS) @ 115VAC 7 0% typical at full load (60% for LPT61) FCC Class B conduc.


Emerson LPT65

ted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Safety ground leakage current: Output Maximum Power: Cross regulation: Adjustment range: Hold-up time: Overlo ad protection: Overvoltage protection: Remote sense: 60W for convection (LPT61 , 35W); 80W with 30CFW forced air (LPT6 1, 55W) ±2% on out.



Part

LPT65

Description

AC-DC / 10W - 85W

Manufacture

Emerson

Datasheet
Download LPT65 Datasheet




 LPT65
Embedded Power for
Business-Critical Continuity
LPT60 Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Triple
RoHS
Rev. 03.24.08
LPT60 Series
1 of 3
Special Features
• Universal input
• 3" x 5" footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Safety
VDE: 0805/EN60950 (IEC950)
11774-3336-1255
(LC #86665)
UL: UL1950
E132002
CSA: CSA 22.2-234 Level 3
LR53982C
NEMKO: EN 60950/EMKO-TUE
P95100123
(74-sec) 203
CB: Certificate and report
1518, 1519, 1520
CE: Mark (LVD)
Electrical Specifications
Input
Input range:
Frequency:
85-264VAC
120-300VDC
47-440Hz
Inrush current:
Input current:
Efficiency:
EMI:
Safety ground
leakage current:
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1.5A max. (RMS) @ 115VAC
70% typical at full load (60% for LPT61)
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum Power:
Cross regulation:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
Remote sense:
60W for convection (LPT61, 35W);
80W with 30CFW forced air (LPT61, 55W)
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.





 LPT65
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Vibration:
Storage temperature:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
-40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated:
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
LPT61
Output
Voltage
+3.3V
+5V
+12V
Minimum
Load
0.7A
0A
0A
Maximum Load
with Convnection
cooling
5A
2.5A
0.5A
Maximum Load
with 30CFM
Forced Air
8.5A
3.0A
1.0A
Peak Load1
9.5A
3.3A
1A
Regulation2
±2%
±2%
±5%
Ripple P/P (PARD)3
50mV
50mV
120mV
LPT62
LPT63
LPT64
LPT65
+5V
+12V
-12V
+5V
+15V
-15V
+5V
+12V
-5V
+5V
+24V
+12V
0.7A
0.3A
0A
0.7A
0.3A
0A
0.7A
0.3A
0A
0.7A
0.1A
0A
7A
3A
0.7A
7A
2.8A
0.7A
7A
3A
0.7A
7A
1.5A
0.7A
8A
3.5A
1A
8A
3.3A
1A
8A
3.5A
1A
8A
2.0A
1A
10A
6A
1.5A
10A
4A
1.5A
10A
6A
1.5A
10A
3A
1.5A
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±7%
±5%
50mV
120mV
120mV
50mV
150mV
150mV
50mV
120mV
50mV
50mV
240mV
120mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
Rev. 03.24.08
LPT60 Series
2 of 3
80W
Output 60W
Power
(Watts) 40W
20W
Power Derating Curve
30 CFM Forced Air Cooling
Natural
Convection
Cooling
40W
30W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C





 LPT65
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.22"
(5.6)
GND
M1
3.00"
(76.2)
2.55"
(64.8)
SK 1
1N
3L
0.22"
(5.6)
4.56"
(115.8)
5.00"
(127)
M2
SK201 _+
Remote Sense
Connector
Voltage
Adj. Pot
SK 2
1
2
3
4
5
6
0.15" (4)
DIA (4 places)
1.69"
(42.9)
0.12"
(3)
Pin Assignments
Connector LPT61 LPT62 LPT63 LPT64 LPT65
SK1-1
SK1-3
Neutral Neutral Neutral Neutral Neutral
Line Line Line Line Line
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
5V +12V +15V +12V +24V
3.3V +5V +5V +5V +5V
3.3V +5V +5V +5V +5V
Common Common Common Common Common
Common Common Common Common Common
+12V -12V -15V -5V
+12V
+Sense +Sense +Sense +Sense +Sense
-Sense -Sense -Sense -Sense -Sense
Mating Connectors
AC Input:
DC Outputs:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense: Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input,
25°C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.75lbs/0.34kg
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Rev. 03.24.08
LPT60 Series
3 of 3
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.



Recommended third-party LPT65 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)