DatasheetsPDF.com

- 85W. LPT81 Datasheet

DatasheetsPDF.com

- 85W. LPT81 Datasheet






LPT81 85W. Datasheet pdf. Equivalent




LPT81 85W. Datasheet pdf. Equivalent





Part

LPT81

Description

AC-DC / 10W - 85W



Feature


Embedded Power for Business-Critical Con tinuity LPT80 Series 80 Watts Total Po wer: Input Voltage: # of Outputs: 55 - 85 Watts 85 - 264 Vac 120 - 370 V dc Triple Rev. 2.20.09_161 LPT80 Serie s  of 3 Special Features • • • • • • • • Power Factor Correction EN61000-3-2 compliant Universal input 3” x 5” f ootprint Remote sense on outputs 1 (& 2 fo.
Manufacture

Emerson

Datasheet
Download LPT81 Datasheet


Emerson LPT81

LPT81; r LPT81) Power fail and remote inhibit W ide range adjustable on outputs 1 (& 2 for LPT81) Built-in Class B EMI filter Overvoltage protection Overload protect ion Electrical Specifications Input In put ra­nge: Frequency: Inrush current: Input current: Efficiency: EMI filter: 85 - 264 Vac; 120 - 300 Vdc 47 - 440 H z  18 A peak @ 115 Vac; < < 36 A peak @ 230 Vac, cold sta.


Emerson LPT81

rt @ 25 °C 1.5 A max. (RMS) @ 115 Vac 7 5% typical at full load FCC Class B con ducted CISPR 22 Class B conducted EN550 22 Class B conducted VDE 0878 PT3 Class B conducted < 1 mA @ 50/60 Hz, 264 Vac input Safety ground leakage current: Output Maximum power: Safety • • • • • • • VDE UL CSA NEMKO AUSTEL CB CE 60950 60950 60950 609 50 60950 Certificate & report Mar.


Emerson LPT81

k LVD Adjustment range: Hold-up time: O verload protection: 60 W for convectio n (LPT81, 55 W); 85 W with 30 CFM force d air 3.3 V - 5.5 V on outputs one (and two 1.8 V - 3.5 V for LPT81) 20 ms @ 8 5 W load, 115 Vac nominal line Short ci rcuit protection on all outputs. Case o verload protected @ 145% above peak rat ing Overvoltage protection: Tracks out puts 1( & 2 for LP.

Part

LPT81

Description

AC-DC / 10W - 85W



Feature


Embedded Power for Business-Critical Con tinuity LPT80 Series 80 Watts Total Po wer: Input Voltage: # of Outputs: 55 - 85 Watts 85 - 264 Vac 120 - 370 V dc Triple Rev. 2.20.09_161 LPT80 Serie s  of 3 Special Features • • • • • • • • Power Factor Correction EN61000-3-2 compliant Universal input 3” x 5” f ootprint Remote sense on outputs 1 (& 2 fo.
Manufacture

Emerson

Datasheet
Download LPT81 Datasheet




 LPT81
Embedded Power for
Business-Critical Continuity
LPT80 Series
80 Watts
Total Power:
Input Voltage:
# of Outputs:
55 - 85 Watts
85 - 264 Vac
120 - 370 Vdc
Triple
Rev. 2.20.09_161
LPT80 Series
 of 3
Special Features
• Power Factor Correction
• EN61000-3-2 compliant
• Universal input
• 3” x 5” footprint
• Remote sense on outputs 1
(& 2 for LPT81)
• Power fail and remote inhibit
• Wide range adjustable on
outputs 1 (& 2 for LPT81)
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
Safety
VDE 60950
UL
60950
CSA
60950
NEMKO 60950
AUSTEL 60950
CB
Certificate & report
CE
Mark LVD
Electrical Specifications
Input
Input ra­nge:
85 - 264 Vac; 120 - 300 Vdc
Frequency:
47 - 440 Hz
Inrush current:
< 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac,
cold start @ 25 °C
Input current:
1.5 A max. (RMS) @ 115 Vac
Efficiency:
75% typical at full load
EMI filter:
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground
leakage current:
< 1 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
60 W for convection (LPT81, 55 W);
85 W with 30 CFM forced air
Adjustment range:
3.3 V - 5.5 V on outputs one
(and two 1.8 V - 3.5 V for LPT81)
Hold-up time:
20 ms @ 85 W load, 115 Vac nominal line
Overload protection: Short circuit protection on all outputs.
Case overload protected @ 145% above peak rating
Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above output setting




 LPT81
Embedded Power for
Business-Critical Continuity
Logic Control
Power failure:
Remote inhibit:
Remote sense:
TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before
loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without remote sense connected.
Reverse connection protected.
Environmental Specifications
Operating temperature: 0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
Temperature coefficient: ± 0.4% per °C
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
- 40° to 85 °C
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G
peak 5 Hz to 500 Hz, operational
> 550,000 hours at full load and 25 °C ambient conditions
Rev. 2.20.09_161
LPT80 Series
 of 3
Ordering Information
Model
Number
Output Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air
Peak Load 1
Regulation 2
LPT81 +3.3 V (1.8 - 3.5 V) 0.7 A
8.0 A
13 A 15 A
+5 V (3.3 - 5.5 V)
0.3 A
4.0 A
13 A 15 A
LPT82
+12 V
+5 V (3.3 - 5.5 V)
0
0.7 A
0.7 A
8.0 A
1.0 A
13 A
1.5 A
15 A
+12 V
0.3 A
3.0 A
4.0 A
4.6 A
LPT83
-12 V
+5 V (3.3 - 5.5 V)
0
0.7 A
0.7 A
8.0 A
1.0 A
13 A
1.5 A
15 A
+15 V
0.3 A
2.4 A
3.2 A
3.7 A
-15 V
0
0.7 A
0.7 A
1A
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum loads are required
5. Total current of all outputs can not exceed 21 A.
±2%
±2%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
Ripple P/P
(PARD)3
50 mV
50 mV
120 mV
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV




 LPT81
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.23 (5.8)
5.00
(127.0)
(4x) .14 (Ø 3.6)
­Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev. 2.20.09_161
LPT80 Series
 of 3
3.00
(76.2)
2.55"
(64.8)
0.22 (5.6)
4.56"
(115.8)
Pin Assignments
Connector
SK1 Pin1
Pin3
SK2 Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
SK3 Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
Pin9
Pin10
LPT81
LPT82/83
Neutral
Neutral
Line Line
V1 (3.3V)
V1 (5 V)
V1 (3.3V)
V1 (5 V)
Common
Common
Common
Common
Common
Common
V2 (5V)
V2 (12/15V)
V2 (5V)
V2 (12/15V)
V3 (12V)
V3 (-12V/15)
+V1 Remote sense +V1 Remote sense
-V1 Remote sense -V1 Remote sense
+Remote inhibit +Remote inhibit
-Remote inhibit -Remote inhibit
+Power fail
+Power fail
Common
Common
No connection
No connection
+V2 sense
No connection
-V2 sense
No connection
No connection
No connection
1
8
5
1
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
10
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
6
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
0.22 (5.6)
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
Mating­ Connectors
AC Input (SK1):
Molex 09-50-8031 (USA)
Molex 09-91-0300 (UK)
PINS: 08-58-0111
DC Outputs (SK2): Molex 09-50-8081 (USA)
09-91-0800 (UK)
PINS: 08-58-0111
Control Signals
(SK3):
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Emerson Network Power Connector Kit #70-841-018
includes all the above.
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”.
3. Mo­­­­unting holes M1, M2 and M3 should be
grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at
factory settings at 115 VAC input, 25 °C unless
otherwise stated.
6. Warranty: 2 year
7. Weight: 0.8 lb. / 0.36 kg
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.






Recommended third-party LPT81 Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)