DatasheetsPDF.com

85 W. NFS40-7605J Datasheet

DatasheetsPDF.com

85 W. NFS40-7605J Datasheet






NFS40-7605J W. Datasheet pdf. Equivalent




NFS40-7605J W. Datasheet pdf. Equivalent





Part

NFS40-7605J

Description

AC-DC / 10W - 85 W



Feature


Embedded Power for Business-Critical Con tinuity NFS40 Series SIngle and triple output Rev.12.12.08_118 NFS40 Series  of 4 Total Power: 40 - 50W Input V oltage: 85 - 264VAC 120 - 370VDC # o f Outputs: Single, triple Electrical Specifications Special Features • 5.0 x 3.0 x 1.2 inch package (1U applicati ons) • Industry standard package • Overvoltage and short ci.
Manufacture

Emerson

Datasheet
Download NFS40-7605J Datasheet


Emerson NFS40-7605J

NFS40-7605J; rcuit protection • 40 W with free air convection • 50 W with 20 CFM forced air • EN55022, EN55011 conducted nois e level A • UL, VDE and CSA safety ap provals • Available RoHS compliant 2 year warranty Input Voltage adjust ability: Line regulation: LL to HL, FL Load regulation: FL to NL Transient res ponse: Temperature coefficient: Overvol tage protection: Output power .


Emerson NFS40-7605J

limit: Short circuit protection: +5 V ou tput on triples Vout on singles Main ou tput Auxiliary outputs Main output Auxi liary outputs +5 V (1.5 - 3 A) All outp uts +5 V output Primary power limited S ingle outputs Multiple outputs Universa l input ±5.0% ±5.0% ±0.2% ±1.0% ±2 .0% ±5.0% ± 120 mV max. dev. 500 µs recovery ±0.02%/°C S3.15 A, 250 Vac I n live and neutral 90 W inpu.


Emerson NFS40-7605J

t power limit Continuous Short term 85-2 64 Vac 120-370 Vdc 47-440 Hz 132 Vac, c old start 264 Vac, cold star 110 Vac, 6 0 Hz 230 Vac, 50 Hz 12 A max. 24 A max. 0.13 mA, max. 0.32 mA, max. Output In put voltage range: Input frequency rang e: Safety • VDE0805/EN60950/ • IEC 950/IEC1010 • File No. 10401-3336-004 4 • License No. 2559 • UL1950 File No. E136005 • CSA C22.2 No. .

Part

NFS40-7605J

Description

AC-DC / 10W - 85 W



Feature


Embedded Power for Business-Critical Con tinuity NFS40 Series SIngle and triple output Rev.12.12.08_118 NFS40 Series  of 4 Total Power: 40 - 50W Input V oltage: 85 - 264VAC 120 - 370VDC # o f Outputs: Single, triple Electrical Specifications Special Features • 5.0 x 3.0 x 1.2 inch package (1U applicati ons) • Industry standard package • Overvoltage and short ci.
Manufacture

Emerson

Datasheet
Download NFS40-7605J Datasheet




 NFS40-7605J
Embedded Power for
Business-Critical Continuity
NFS40 Series
SIngle and
triple output
Rev.12.12.08_118
NFS40 Series
 of 4
Total Power: 40 - 50W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Single, triple
Special Features
• 5.0 x 3.0 x 1.2 inch package
(1U applications)
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
conducted noise level A
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
• File No. 10401-3336-0044
• License No. 2559
• UL1950 File No. E136005
• CSA C22.2 No. 950
• File No. LR41062C
Electrical Specifications
Input
Voltage adjustability:
Line regulation:
LL to HL, FL
Load regulation:
FL to NL
Transient response:
+5 V output on triples
Vout on singles
Main output
Auxiliary outputs
Main output
Auxiliary outputs
+5 V (1.5 - 3 A)
Temperature coefficient:
Overvoltage protection:
Output power limit:
Short circuit protection:
Output
Input voltage range:
All outputs
+5 V output
Primary power limited
Single outputs
Multiple outputs
Universal input
Input frequency range:
Max. input surge current:
Safety ground leakage current:
132 Vac, cold start
264 Vac, cold star
110 Vac, 60 Hz
230 Vac, 50 Hz
±5.0%
±5.0%
±0.2%
±1.0%
±2.0%
±5.0%
± 120 mV max. dev.
500 µs recovery
±0.02%/°C
S3.15 A, 250 Vac In live and neutral
90 W input power limit
Continuous
Short term
85-264 Vac
120-370 Vdc
47-440 Hz
12 A max.
24 A max.
0.13 mA, max.
0.32 mA, max.




 NFS40-7605J
Embedded Power for
Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC Charateristics (11, 12)
Conducted emissions:
EN55022, FCC part 15
Radiated emissions:
ESD  air:
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
EN55022
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-2, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
General Specifications
Hold-up time:
Efficiency:
110 Vac, 40 W
230 Vac, 40 W
Isolation voltage:
Input/output
Input/chassis
Switching frequency:
Variable
Approvals and standards: (see VDE0805, EN60950, IEC950, IEC1010,
Notes 9, 13)
UL1950, CSA C22.2 No. 950
Weight:
280 g (9.88 oz)
MTBF demonstrated:
MIL-HDBK-217E
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
14 ms
110 ms
70% typical
3000 Vac
1500 Vac
170,000 hours
Environmental Specifications
Thermal performance:
Operating
(See notes 8, 10)
Relative humidity:
Altitude:
Vibration (See Note 11):
Non-operating
50 °C ambient temp.,
convection cooled
Forced air cooling
+50 °C to +70 °C ambient
Peak (60 seconds)
Non-condensing
Operating
Non-operating
5-500 Hz
0° C to +70 °C
-40 °C to +85 °C
40 W
50 W @ 20 CFM
Derate linearly to 50% load
60W
5 to 80% RH
10,000 feet max.
40,000 feet max.
2.4 G rms peak
Rev.12.12.08_118
NFS40 Series
 of 4




 NFS40-7605J
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Max (1)
+5.1 V (A)
3A
+12 V (B)
2A
–12 V (C)
0.35 A
+5.1 V (A)
4A
+12 V (B)
0.35 A
-12 V (C)
0.35 A
+5.1 V (A)
3A
+12 V (B)
2A
-5.0 V (C)
0.35 A
+5.1 V (A)
3A
+15 V (B)
2A
–15 V (C)
0.35 A
3.3 V
6A
+5.1 V
6A
+12.0 V
3.3 A
+15.0 V
2.6 A
+24.0 V
1.6 A
Output Currents
Peak (2)
7A
3A
1A
7A
1A
1A
7A
3A
1A
7A
2.5 A
1A
12 A
12 A
5A
4A
2.5 A
Fan (3)
5A
2A
0.5 A
5A
0.5 A
0.5 A
5A
2A
0.5 A
5A
2A
0.5 A
8A
8A
4A
3.3 A
2A
Ripple (4)
50 mV
120 mV
120 mV
 50 mV
120 mV
120 mV
50 mV
120 mV
50 mV
50 mV
150 mV
150 mV
100 mV
100 mV
120 mV
150 mV
240 mV
Total
Regulation (5)
Model Numbers (13, 14, F)
±2.0%
NFS40-7608J (5,6)
±5.0%
±5.0%
±2.0%
±5.0%
NFS40-7628J (12)
+5.0%
±2.0%
NFS40-7607J (5,6)
±5.0%
±5.0%
±2.0%
±10.0%/-3.0%
±5.0%
±2.0%
±2.0%
NFS40-7610J (5,6)
NFS40-76S3J
NFS40-7605J
±2.0%
NFS40-7612J
±2.0%
NFS40-7615J
±2.0%
NFS40-7624J
Rev.12.12.08_118
NFS40 Series
 of 4
Notes
1 Natural convection cooled, 40 W maximum.
2 Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth
using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, 0.25<I(A)/
I(B)<5.0 to maintain stated regulation. This does not apply to the NFS40-7628J
power supply as it has regulated auxiliary outputs.
6 A minimum load of 0.5 A is required on the +5 V output to obtain full current
from the negative output.
7 The NFS40 offers the possibility of power sharing between outputs. Consult
factory for details.
8 Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 110 oC and no
semiconductor case temperature should exceed 115 oC.
9 A 4 W minimum load is recommended to achieve the design MTBF.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major
resonances.
12 The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The
loading conditions in Notes 5 and 6 do not apply.
13 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com to find a suitable alternative.
J1
Pin 1
Pin 2
J2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
P1(c)
Pin 1
Pin Connections
-7608J, -7628J -7607J
-7610J
AC Live
AC Live
AC Live
AC Neutral AC Neutral AC Neutral
SINGLES
AC Line
AC Neutral
+12 V
+5.1 V
+5.1 V
Return
Return
-12 V
+12 V
+5.1 V
+5.1 V
Return
Return
-5 V
+15 V
+5.1 V
+5.1 V
Return
Return
-15 V
+Vout
+Vout
+Vout
Return
Return
Return
Safety Ground
DERATING CURVE
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
NATURAL
CONVECTION
COOLING
25W
20W
0C
10C 20C 30C
40C 50C 60C
70C






Recommended third-party NFS40-7605J Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)