Document
Embedded Power for Business-Critical Continuity
NLP65 Series
Single, dual, and triple output
Total Power: Input Voltage: # of Outputs:
Rev.12.12.08_102 NLP65 Series of 4
65 - 75W 85 - 264 Vac 120 - 370 Vdc* Single, dual, triple
Electrical Specifications
Special Features
• Universal Input • 3” x 5” footprint • Low profile fits 1U applications • EN61000-3-2 compliance option (HCC) • Overvoltage and short circuit protection • 65 W with free air convection cooling • EN55022, EN55011 conducted emissions level B • EN61000-4-2,-3,-4, -5, -6 immunity compliant • RoHS compliant • LPX80 enclosure kit available • 2 year warranty
Input
Input voltage range: Universal input (see Note 2) NLP65-76xx version only 120 Vac 230 Vac 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac, with PFC 230 Vac, with PFC 120 Vac, without PFC 230 Vac, without PFC UL/IEC127 Main output Auxiliary outputs At turn-on Main output 25% step at 0.1 A/µs Main outputs Cyclic operation Single and multiple 85-264 Vac 120-370 Vdc 47-63 Hz 17 A max. 32 A max 0.7 mA 1.4 mA 1.4 mA 0.51 A rms 1.40 A rms 0.80 A rms S3.15 A, 250 Vac In live and neutral ±2.0% ±5.0% 1.0 s, max 5.0% or 250 mV max. dev., 1ms max. recovery to 1% ±0.02%/°C 125%, ±10% Continuous (See Note 6)
Input frequency range: Input current: (cold start) Safety ground leakage current: Input current:
Input fuse:
Output
Total regulation: (line and load)
Safety
• • • • • VDE0805/EN60950/IEC950 File No. 1040100-3336-0096 License No. 114404 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C China Compulsory Certification 60950
Rise time: Transient response:
Temperature coefficient: Overvoltage protection: Short circuit protection: Minimum output current:
*NLP65-76xx version only
Embedded Power for Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics (11, 12)
Conducted emissions: ESD air: ESD contact: Surge: Fast transients: Radiated immunity: Conducted immunity: EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-2, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac, 65 W Input/output Input/chassis Level B Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2 16 ms @ 65 W 78 ms @ 65 W 72% typical 3000 Vac 1500 Vac 100 kHz, ±5 kHz
Rev.12.12.08_102 NLP65 Series of 4
General Specifications
Hold-up time: Efficiency: Isolation voltage: Switching frequency:
Fixed Approvals and standards: (see EN60950, VDE0805 Notes 9, 13) IEC950, UL1950, CCC60950 CSA C22.2 No. 950 Weight: 283 g (10 oz) MTBF demonstrated: MIL-HDBK-217F
150,000 hours min
Environmental Specifications
Thermal performance: (See notes 1, 3, 10) Operating (See derating curve) Non-operating 50 °C - 70 °C ambient, convection cooled 0 °C to 50 °C, ambient, convection cooled 0° C to +70 °C
75W DERATING CURVE Output Power (Watts) 20 CFM FORCED AIR COOLING 65W
-40 °C to +85 °C Derate to 50% load 65 W
0 °C to 50 °C, ambient 75 W 20CFM forced air (See Note 10) Peak (0 °C to 50 °C, 60 s) See table Relative humidity: Altitude: Vibration (See Note 5): Shock Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5 to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV
0°C
NATURAL CONVECTION COOLING
38W 32W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
Embedded Power for Business-Critical Continuity
Output Voltage +5 V (IA) +12 V (IB) –12 V +5 V (IA) +15 V (IB) –15 V +5 V +24 V +12 V +5 V (IA) +24 V (IB) +5 V (IA) +12 V (IB) +5 V +12 V +15 V +24 V
Output Current Max (1) 7.5 A 2.5 A 0.65 A 7.5 A 2.2 A 0.65 A 7.0 A 1.5 A 0.7 A 7A 2A 7A 2.5 A 10 A 5.4 A 4.4 A 2.7 A Peak (3) 9.1 A 3.3 A 0.81 A 9.1 A 2.9 A 0.85 A 9.1 A 2.6 A 1.0 A 9.1 A 2.6 A 9.1 A 3.3 A 13 A 7A 5.7 A 3.5 A Fan (10) 8A 3A 0.8 A 8A 2.5 A 0.8 A 8.0 A 2.0 A 1.0 A 8A 2A 8A 3A 12 A 6.5 A 5.3 A 3.5 A
Ripple (4) 50 mV 150 mV 120 mV 50 mV 150 mV 150 mV 50 mV 240 mV 120 mV 50 mV 240 mV 50 mV 150 mV 50 mV 120 mV 150 mV 240 mV
Total Non-harmonic Regulation (6) Corrected ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% NLP65-7605J NLP65-7612J NLP65-7615J NLP65-7624J NLP65-7629J NLP65-7620J NLP65-3322J(15) NLP65-7610J NLP65-7608J
Harmonic Corrected NLP65-9608J
Ground Pin (12, 14, 17) NLP65-X608GJ
Rev.12.12.08_102 NLP65 Series of 4
NLP65-9610J
NLP65-X610GJ
NLP65-9620J NLP65-9629J NLP65-9605J NLP65-9612J NLP65-9615J NLP65-9624J
NLP65-X620GJ NLP65-X629GJ NLP65-X605GJ NLP65-X612GJ NLP65-X615GJ NLP65-X624GJ
Notes
1 Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65X610J must not exceed 62.5 Watts continuous output power with natural convection. Model NLP65-X620J not to exceed 65 Watts continuous output power with natural convection. Model NLP65-3322J must not exceed 60 Watts continuous output power with natural convection. 2 When the input .