Document
Embedded Power for Business-Critical Continuity
TLP150 Series
Single output
Rev.7.8.09_146 TLP150 of 4
Total Power: 150 W Input Voltage: 85 - 264 VAC # of Outputs: Single
RoHS
Special Features
• • • • • • • • • • • • 150 W on main channel with only 200 LFM Low profile fits 1U applications Active PFC and EN61000-3-2 compliant Integrated Or-ing diode Active current sharing Integrated control and monitoring features Overcurrent, overvoltage and overtemperature protection Compliance to EN55022-B conducted noise standard 12 V fan output 5 V standby output (optional) RoHS compliant 2 year warranty
Electrical Specifications
Output
Adjustment range: Total regulation: (line and load) Turn-on delay Transient response Main output Auxiliary outputs Fan output @120 Vac input Main output 25% to 75% step at 0.5 A/µs Main outputs Current limited Singles See Note 9 See Note 9 Universal input 264 Vac (cold start) 264 Vac, 50 Hz 120 Vac @ 250 W 230 Vac @ 250 W UL/iEC127 ± 10% ± 3% ± 5% ± 10% 2.0 s max. 5% max. dev., 1 ms max. recovery to 1% ±0.02%/°C 125% ± 5% Continuous 0A 12 V @ 0.5 A 5 V @ 1.0 A 85-264 Vac 47-63 Hz 40 A max. 1 mA 1.8 A rms 0.8 A rms T 3.15 A, 250 Vac
Temperature coefficient Overvoltage protection Short circuit protection Minimum output current Fan voltage output Standby output
Input
Input voltage range:
Safety
• VDE EN60950-1/IEC60950-1 • UL60950-1/CSA22.2 No. 60950-1
Input frequency range: Input surge current: Safety ground leakage current: Input current: Input fuse:
Embedded Power for Business-Critical Continuity
EMC Characteristics
Conducted emissions: harmonic current correction: ESD air: ESD contact: Fast transients: Surge: Conducted immunity: EN55022, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-6 85 Vac @ 60 Hz 115 Vac @ 150 W 230 Vac @ 150 W Input/output Input/chassis Level B Compliant Level 3 Level 3 Level 4 Level 4 Level 3 20 ms @ 150 W 81% typ. 84% typ. 3000 Vac 1500 Vac
Rev.7.8.09_146 TLP150 of 4
General Specifications
Hold-up time: Efficiency: Isolation voltage: Safety approvals: (see note 6) Weight: MTBF (@25 ºC)
UL/cUL UL60950-1/CSA22.2 No. 60950-1 VDE EN60950-1/IEC60950-1 260g (9.2 oz) Telcordia SR-332 MIL-HDBK-217F 900,000 hours min. 350,000 hours min.
Environmental Specifications
Thermal performance: Operating ambient, (See derating curve) Non-operating 0 °C to 50 °C ambient, 200 LFM forced air 0 °C to 50 °C ambient, convection cooled 50 °C to 70 °C ambient, Relative humidity: Altitude: Vibration (See Note 7): Shock: Non-condensing Operating Non-operating 5 - 500 Hz per MIL-STD-810E 0° C to +70 °C -40 °C to +85 °C 150 W 100 W Derate linearly to 50% load 5 - 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV
Embedded Power for Business-Critical Continuity
Ordering Information
Output Voltage 12 V 24 V 36 V 48 V Notes Output Currents Min 0A 0A 0A 0A Max (free air)(1, 4) Max (forced air) (2,4) 8.4 A 4.2 A 2.7 A 2.1 A 12.5 A 6.3 A 4.2 A 3.2 A 120 mV 240 mV 360 mV 480 mV Ripple (3) Total Regulation ± 3.0% ± 3.0% ± 3.0% ± 3.0% M����� odel Numbers �������� (9, 10)
Rev.7.8.09_146 TLP150 of 4
TLP150R-96S12J TLP150R-96S24J TLP150R-96S36J TLP150R-96S48J
1 Free air convection. Maximum continuous output power not to exceed 100 W. Refer to DERATING CURVE Output Power (Watts) Figure 1 for the derating curve. 2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W. 150 W 3 Figure is peak-to-peak for room temperature rating. Output noise measurements are 200 LFM (1.0 m/s) made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF FORCED AIR COOLING tantalum capacitor and a 0.1 µF ceramic capacitor. 100 W 4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed 115 °C and no semi-conductor case temperature should exceed 120 °C. 5 No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with NATURAL CONVECTION COOLING radiated EMI specifications may require mounting in a suitable enclosure. 6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G 0W 8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output and/or remote ON/OFF control is required 0C 10 C 20 C 30 C 40 C 50 C e.g. TLP150R-96S12FJ. 9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status. 10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. The ‘Y’ suffix indicates TSE RoHS 5/6 (non Pb-free) compliant versions may be availabl.