KK7101
GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR
Description
The KK7101N/D is designed for use in earth l...
KK7101
GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR
Description
The KK7101N/D is designed for use in earth leakage circuit interrupters for operation directly off the AC Line in breakers. It contains pre
regulator, main
regulator, after
regulator, differential amplifier, level comparator, latch circuit. The input in the differential amp latch circuit. The input in the differential amplifier is connect to the secondary node of zero current transformer. The level comparator generates high level when earth leakage current is greater than some level.
KK7101
Feature
Low Power Consumption (PD=5mW) 100V/200V 100V/200V Common Built-in Voltage
Regulator High Gain Differential Amplifier High Input Sensitivity Minimum External Parts Large Surge Margin Wide Operating Temperature Range (TА= -40 to 85°C) High Noise Immunity Meet U. L. 943 standards
ORDERING INFORMATION KK7101N Plastic KK7101D SOIC KK7101S SIP-8 TA = -40° to 85° C for all packages.
Absolute Maximum Ratings
Supply Voltage Supply Current www.DataSheet4U.com Power Dissipation Operating Temperature Storage Temperature
20V 8mA 200m W - 40 to 85°C - 55 to 125°C
Pin Configuration (Top View)
KK7101
Block Diagram
www.DataSheet4U.com
KK7101
Recommended Operating Condition: TA=-30°C to 80°C
PARAMETER Supply Voltage Vs-GND Capacitor OS-GND Capacitor SYMBOL V+ Cvs Cos MIN. 12 1 TYP. MAX UNIT V µF µF
1
Electrical Characteristics
PARAMETER
SYMBOL
CONDTIONS V+=12V, VR - VI = 30 mV V+ = ...