Feature |
Baza Porad Serwisowych
RSN3306A power amp
MUTE
PROTECTION PHASE CORRECTION OUT DC DET.
+
OVER LOAD
IC601 RSN3306A
AC IN DET.
GND
POWER AMP (FRONT)
LOAD SHORT DET. -DI +DI SENS SENS
PHASE CORRECTION
+
-
26
25
-38.8V
24
-38.8V
23
-0.6V
22
-12.3V
21
0V
20
-0.3V
19
-0.3V
18
5.2V
17
-0.3V
16
-0.3V
15
14
13
-4.4V
12
0V
11
-12.6V
10
0V
9
-25.2V
8
24.8V
7
0V
6
-41.4V
5
41.4V
4
-18V
3
17.6V
2
-40V
1
39.8V
-14.1V
C616 10µ/100V
D602 SB360650IT
R622 120k
C617 22µ/63V C618 2µ2/100V R621 18k N R623 680k R607 56k C609 220p R647 220 C607 10p R608 56k C608 10p
D601 SB360. |