Electronic pressure sensor
Pressure sensors
PA3029
Electronic pressure sensor PA30
Plug and socket Process connection G¼ I Analogue output
Measu...
Description
Pressure sensors
PA3029
Electronic pressure sensor PA30
Plug and socket Process connection G¼ I Analogue output
Measuring range -1...0 bar
Application Electrical design Output Operating voltage Reverse polarity protection Overload protection [V]
Type of pressure: relative pressure Liquids and gases DC 4...20 mA analogue 9.6...32 DC ¹) yes yes 4...20 mA max. (Ub - 9.6 V) x 50; 720 at Ub = 24 V 10 30
Analogue output Load for analogue output [ohms] Pressure rating [bar] Bursting pressure min. [bar] Accuracy / deviations (in % of the span) Characteristics deviation *) Repeatability **) Long-term stability ***) Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K) Greatest TEMPCO of the zero point Greatest TEMPCO of the span
< ± 0.25 (BFSL) / < ± 0.5 (LS) < 0.1 < ± 0.05
0.1 0.2
ifm electronic gmbh Teichstraße 4 45127 Essen — We reserve the right to make technical alterations without prior notice. — GB — PA3029 — 07.08.2007
www.DataSheet.in
PA3029
Step response time analogue output [ms] Ambient temperature [°C] Medium temperature [°C] Storage temperature [°C] Protection Insulation resistance [MΩ] Shock resistance Vibration resistance Min. pressure cycles EMC 3 -25...80 -25...90 ****) -40...100 IP 65, III > 100 (500 V DC) DIN IEC 68-2-27:50 g (11 ms) DIN IEC 68-2-6:20 g (10...2000 Hz) 100 million EN 61000-4-2 ESD: 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated: 30 V/m EN 61000-4-4 Burst: 2 kV EN 61000-4-6 HF conducted: 10 V accor...