SAW Filter. 813-SL60.0M-21 Datasheet

813-SL60.0M-21 Datasheet PDF, Equivalent


Part Number

813-SL60.0M-21

Description

IF SAW Filter

Manufacture

Oscilent Corporation

Total Page 3 Pages
PDF Download
Download 813-SL60.0M-21 Datasheet PDF


813-SL60.0M-21 Datasheet
Oscilent Corporation IF SAW Filter | 813-SL60.0M-21
Page 1 of 3
Part Number
813-SL60.0M-21
TYPE :
60.0MHz IF SAW Filter
Package
13.3 x 6.5 SMD
Application
IF SAW Filter
IF SAW Filter
Last Modified
Jan 01, 2007
PART NUMBER :
813-SL60.0M-21
OPERATING CONDITIONS / ELECTRICAL CHARACTERISTICS
PARAMETERS
Minimum
Typical
Center Frequency (Fo)
- 60.0
Insertion Loss at Fo
- 24.7
Source Impedance (single ended)*
- 50
Load Impedance (single ended)*
- 50
Temperature Coefficient
- -94
Amplitude Ripple (Fo+/-10 MHz)
- 0.7
1dB Bandwidth
20.0 21.2
Relative Attenuation:
-
Fo+/-9.50 MHz
-0
Fo+/-10.90 MHz
- 1.5
Fo+/-19.5 MHz
38 45
Fo+/20MHz
38 45
Fo+/-40 MHz
40 45
From DC to Fo - 29.5 MHz
40 45
From Fo+29.75 to 100MHz
40 43
Absolute Delay at Fo
- 0.93
Group Delay Variation (Fo+/-10MHz)
- 30
Operating Temp
-45 -
Storage Temp
-45 -
Maximum
-
26.0
-
-
-
1.0
-
-
-
-
-
-
-
-
-
70
+85
+85
*With Matching Network (Ref. Testing Environment Circuit as Shown Below).
Those impedances could be modified with different impedance values and/or structures, if necessary
PACKAGE OUTLINE (mm)
Units
MHz
dB
ohm
ohm
ppm/C
dBp-p
MHz
dB
dB
dB
dB
dB
dB
dB
us
ns
C
C
www.DataSheet.in

813-SL60.0M-21 Datasheet
Oscilent Corporation IF SAW Filter | 813-SL60.0M-21
Page 2 of 3
TEST CIRCUIT
TEST FIXTURE AND VALUES/SOURCE AND LOAD IMPEDANCE 50 ohm
INPUT:
L1: 120 nH Q>40
OUTPUT:
L2: 150 nH Q>40; C2: 20 pF
FREQUENCY RESPONSE
www.DataSheet.in


Features Datasheet pdf Oscilent Corporation IF SAW Filter | 813 -SL60.0M-21 Page 1 of 3 IF SAW Filter Part Number Package Application Last M odified 813-SL60.0M-21 TYPE : 13.3 x 6.5 SMD IF SAW Filter Jan 01, 2007 6 0.0MHz IF SAW Filter PART NUMBER : 813 -SL60.0M-21 OPERATING CONDITIONS / ELEC TRICAL CHARACTERISTICS PARAMETERS Cente r Frequency (Fo) Insertion Loss at Fo S ource Impedance (single ended)* Load Im pedance (single ended)* Temperature Coe fficient Amplitude Ripple (Fo+/-10 MHz) 1dB Bandwidth Relative Attenuation: Fo +/-9.50 MHz Fo+/-10.90 MHz Fo+/-19.5 MH z Fo+/20MHz Fo+/-40 MHz From DC to Fo - 29.5 MHz From Fo+29.75 to 100MHz Absol ute Delay at Fo Group Delay Variation ( Fo+/-10MHz) Operating Temp Storage Temp 38 38 40 40 40 -45 -45 0 1.5 45 45 45 45 43 0.93 30 Minimum 20.0 Typical 60.0 24.7 50 50 -94 0.7 21.2 70 +85 +85 dB dB dB dB dB dB dB us ns C C Maximum 26. 0 1.0 Units MHz dB ohm ohm ppm/C dBp-p MHz *With Matching Network (Ref. Testi ng Environment Circuit as Shown Below). Those impedances could .
Keywords 813-SL60.0M-21, datasheet, pdf, Oscilent Corporation, IF, SAW, Filter, 13-SL60.0M-21, 3-SL60.0M-21, -SL60.0M-21, 813-SL60.0M-2, 813-SL60.0M-, 813-SL60.0M, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)